target: Don't call TFO->write_pending if data_length == 0
authorRoland Dreier <roland@purestorage.com>
Tue, 14 Oct 2014 21:16:24 +0000 (14:16 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 6 Dec 2014 23:55:38 +0000 (15:55 -0800)
commit 885e7b0e181c14e4d0ddd26c688bad2b84c1ada9 upstream.

If an initiator sends a zero-length command (e.g. TEST UNIT READY) but
sets the transfer direction in the transport layer to indicate a
data-out phase, we still shouldn't try to transfer data.  At best it's
a NOP, and depending on the transport, we might crash on an
uninitialized sg list.

Reported-by: Craig Watson <craig.watson@vanguard-rugged.com>
Signed-off-by: Roland Dreier <roland@purestorage.com>
Signed-off-by: Nicholas Bellinger <nab@linux-iscsi.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/target/target_core_transport.c

index 9232c77..e6463ef 100644 (file)
@@ -2230,7 +2230,7 @@ transport_generic_new_cmd(struct se_cmd *cmd)
         * and let it call back once the write buffers are ready.
         */
        target_add_to_state_list(cmd);
-       if (cmd->data_direction != DMA_TO_DEVICE) {
+       if (cmd->data_direction != DMA_TO_DEVICE || cmd->data_length == 0) {
                target_execute_cmd(cmd);
                return 0;
        }