[Model] All
[BinType] AP
[Customer] OPEN
[Issue#] N/A
[Request] Internal
[Occurrence Version] N/A
[Problem] register gatt server -> bluetoothd terminated abnormally -> unregister gatt server ->
bt-frwk recovery BT-> register gatt server -> crash
[Cause & Measure] After BT disabled, gatt server is not deinitialized properly.
[Checking Method] n/a
[Team] IoT Hub
[Developer] Injun Yang
[Solution company] Samsung
[Change Type] Specification change
Change-Id: I6f4356e12e05073656d56302d7e6c39883fc96f2
Signed-off-by: injun.yang <injun.yang@samsung.com>
Signed-off-by: DoHyun Pyun <dh79.pyun@samsung.com>
if (err != NULL) {
BT_ERR("D-Bus API failure: errCode[%x], message[%s]",
err->code, err->message);
- if (err->code == G_DBUS_ERROR_SERVICE_UNKNOWN) {
+ if (err->code == G_DBUS_ERROR_SERVICE_UNKNOWN ||
+ g_strrstr(err->message, BT_ERROR_DOES_NOT_EXIST)) {
g_clear_error(&err);
goto done;
}
#define BT_ERROR_BUSY "InProgress"
#define BT_ERROR_INVALID_PARAM "InvalidArguments"
#define BT_ERROR_ALREADY_EXIST "AlreadyExists"
+#define BT_ERROR_DOES_NOT_EXIST "DoesNotExist"
#define BT_ERROR_ALREADY_CONNECTED "Already Connected"
#define BT_ERROR_NO_MEMORY "No memory"
#define BT_ERROR_NO_DATA "No data"