Check whether dbus name is acquired normally. 06/183506/1
authorDeokhyun Kim <dukan.kim@samsung.com>
Fri, 6 Jul 2018 05:52:43 +0000 (14:52 +0900)
committerinjun.yang <injun.yang@samsung.com>
Fri, 6 Jul 2018 05:52:43 +0000 (14:52 +0900)
commitbd54a9eab645f52272c53a49e269cbf310a5ec8d
tree9082a0ec2b171d2171dbc1b34ff886442785c827
parent3266f4d586ff855272c076c277c7894d4d1db3c3
Check whether dbus name is acquired normally.

[Problem] bt-service is terminated before dbus method is called.
[Cause & Measure] dbus own_name is too delayed when system is busy.
  Call g_bus_own_name with callback functions. And then terminate bt-service
  after checking bus_name acquired.
[Checking Method] Repeat to on/off BT

Change-Id: I63b2d8d0714217f21d72d77b7d6f2afb8a75ea1d
bt-service/bt-request-handler.c
bt-service/bt-service-main.c
bt-service/include/bt-request-handler.h