[framework/connectivity/bluez.git] / doc / mgmt-api.txt
index 51c9b46..725e8cc 100644 (file)
@@ -4,6 +4,92 @@ Bluetooth Management API
 Copyright (C) 2008-2009  Marcel Holtmann <marcel@holtmann.org>
 
 
+Overview
+========
+
+This document describes the format of data used for communicating with
+the kernel using a so-called Bluetooth Management sockets. These sockets
+are available starting with Linux kernel version 3.4
+
+The following kernel versions introduced new commands, new events or
+important fixes to the Bluetooth Management API:
+
+Linux kernel v3.4      Version 1.0
+Linux kernel v3.5      Version 1.1
+Linux kernel v3.7      Version 1.2
+Linux kernel v3.9      Version 1.3
+Linux kernel v3.13     Version 1.4
+Linux kernel v3.15     Version 1.5
+Linux kernel v3.16     Version 1.6
+Linux kernel v3.17     Version 1.7
+Linux kernel v3.19     Version 1.8
+
+Version 1.1 introduces Set Device ID command.
+
+Version 1.2 introduces Passkey Notify event.
+
+Version 1.3 does not introduce any new command or event.
+
+Version 1.4 introduces Set Advertising, Set BR/EDR, Set Static Address
+and Set Scan Parameters commands. The existing Set Discoverable command
+gained an extra setting for limited discoverable mode. The device name
+is now provided in the scan response data for Low Energy.
+
+Version 1.5 introduces Set Secure Connections, Set Debug Keys, Set Privacy
+and Load Identity Resolving Keys commands. It also introduces New Identity
+Resolving Key and New Signature Resolving Key events.
+
+Version 1.6 introduces Get Connection Information command. It also updates
+the Device Found event to combine advertising data and scan response data
+into a single event.
+
+Version 1.7 introduces Get Clock Information, Add Device, Remove Device,
+Load Connection Parameters, Read Unconfigured Index List, Read Controller
+Configuration Information, Set External Configuration and Set Public Address
+commands. It also introduces Device Added, Device Removed, New Connection
+Parameter, Unconfigured Index Added, Unconfigured Index Removed and New
+Configuration Options events. The existing Set Debug Keys command gained
+an extra setting for enabling SSP debug mode.
+
+Version 1.8 introduces Start Service Discovery command. It also adds new
+Long Term Key types for LE Secure Connection feature.
+
+
+Example
+=======
+
+The Bluetooth management sockets can be created by setting the hci_channel
+member of struct sockaddr_hci to HCI_CHANNEL_CONTROL (3) when creating a
+raw HCI socket. In C the needed code would look something like the following:
+
+int mgmt_create(void)
+{
+       struct sockaddr_hci addr;
+       int fd;
+
+       fd = socket(PF_BLUETOOTH, SOCK_RAW | SOCK_CLOEXEC | SOCK_NONBLOCK,
+                                                                BTPROTO_HCI);
+       if (fd < 0)
+               return -errno;
+
+       memset(&addr, 0, sizeof(addr));
+       addr.hci_family = AF_BLUETOOTH;
+       addr.hci_dev = HCI_DEV_NONE;
+       addr.hci_channel = HCI_CHANNEL_CONTROL;
+
+       if (bind(fd, (struct sockaddr *) &addr, sizeof(addr)) < 0) {
+               int err = -errno;
+               close(fd);
+               return err;
+       }
+
+       return fd;
+}
+
+The process creating the mgmt socket is required to have the
+CAP_NET_ADMIN capability (e.g. root would have this).
+
+
 Packet Structures
 =================
 
@@ -54,6 +140,15 @@ and Command Complete events:
 0x0D   Invalid Parameters
 0x0E   Disconnected
 0x0F   Not Powered
+0x10   Cancelled
+0x11   Invalid Index
+
+As a general rule all commands generate the events as specified below,
+however invalid lengths or unknown commands will always generate a
+Command Status response (with Unknown Command or Invalid Parameters
+status). Sending a command with an invalid Controller Index value will
+also always generate a Command Status event with the Invalid Index
+status code.
 
 
 Read Management Version Information Command
@@ -65,6 +160,11 @@ Read Management Version Information Command
        Return Parameters:      Version (1 Octets)
                                Revision (2 Octets)
 
+       This command returns the Management version and revision.
+       Besides, being informational the information can be used to
+       determine whether certain behavior has changed or bugs fixed
+       when interacting with the kernel.
+
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
@@ -84,6 +184,9 @@ Read Management Supported Commands Command
                                Event2 (2 Octets)
                                ...
 
+       This command returns the list of supported Management commands
+       and events.
+
        The commands Read Management Version Information and Read
        management Supported Commands are not included in this list.
        Both commands are always supported and mandatory.
@@ -104,6 +207,10 @@ Read Controller Index List Command
        Return Parameters:      Num_Controllers (2 Octets)
                                Controller_Index[i] (2 Octets)
 
+       This command returns the list of currently known controllers.
+       Controllers added or removed after calling this command can be
+       monitored using the Index Added and Index Removed events.
+
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
@@ -123,26 +230,55 @@ Read Controller Information Command
                                Name (249 Octets)
                                Short_Name (11 Octets)
 
-       If not short name is set the Short_Name parameter will be empty
+       This command is used to retreive the current state and basic
+       information of a controller. It is typically used right after
+       getting the response to the Read Controller Index List command
+       or an Index Added event.
+
+       The Address parameter describes the controllers public address
+       and it can be expected that it is set. However in case of single
+       mode Low Energy only controllers it can be 00:00:00:00:00:00. To
+       power on the controller in this case, it is required to configure
+       a static address using Set Static Address command first.
+
+       If the public address is set, then it will be used as identity
+       address for the controller. If no public address is available,
+       then the configured static address will be used as identity
+       address.
+
+       In the case of a dual-mode controller with public address that
+       is configured as Low Energy only device (BR/EDR switched off),
+       the static address is used when set and public address otherwise.
+
+       If no short name is set the Short_Name parameter will be empty
        (begin with a nul byte).
 
-       Current_Settings & Supported_Settings is a bitmask with
+       Current_Settings and Supported_Settings is a bitmask with
        currently the following available bits:
 
-               1       Powered
-               2       Connectable
-               3       Fast Connectable
-               4       Discoverable
-               5       Pairable
-               6       Link Level Security (Sec. mode 3)
-               7       Secure Simple Pairing
-               8       Basic Rate/Enhanced Data Rate
-               9       High Speed
-               10      Low Energy
+               0       Powered
+               1       Connectable
+               2       Fast Connectable
+               3       Discoverable
+               4       Bondable
+               5       Link Level Security (Sec. mode 3)
+               6       Secure Simple Pairing
+               7       Basic Rate/Enhanced Data Rate
+               8       High Speed
+               9       Low Energy
+               10      Advertising
+               11      Secure Connections
+               12      Debug Keys
+               13      Privacy
+               14      Controller Configuration
+               15      Static Address
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Set Powered Command
 ===================
@@ -152,6 +288,10 @@ Set Powered Command
        Command Parameters:     Powered (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to power on or off a controller. The
+       allowed Powered command parameter values are 0x00 and 0x01. All
+       other values will return Invalid Parameters.
+
        If discoverable setting is activated with a timeout, then
        switching the controller off will expire this timeout and
        disable discoverable.
@@ -159,6 +299,10 @@ Set Powered Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Discoverable Command
 ========================
@@ -169,21 +313,43 @@ Set Discoverable Command
                                Timeout (2 Octets)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to set the discoverable property of a
+       controller. The allowed Discoverable command parameter values
+       are 0x00, 0x01 and 0x02. All other values will return Invalid
+       Parameters.
+
        Timeout is the time in seconds and is only meaningful when
-       Discoverable is set to 1.
+       Discoverable is set to 0x01 or 0x02. Providing a timeout
+       with 0x00 return Invalid Parameters. For 0x02, the timeout
+       value is required.
+
+       The value 0x00 disables discoverable, the value 0x01 enables
+       general discoverable and the value 0x02 enables limited
+       discoverable.
+
+       This command is only available for BR/EDR capable controllers
+       (e.g. not for single-mode LE ones). It will return Not Supported
+       otherwise.
 
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
        However using a timeout when the controller is not powered will
-       return an error.
+       return Not Powered error.
 
        When switching discoverable on and the connectable setting is
-       off it will return an error.
+       off it will return Rejected error.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Set Connectable Command
 =======================
@@ -193,6 +359,19 @@ Set Connectable Command
        Command Parameters:     Connectable (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to set the connectable property of a
+       controller. The allowed Connectable command parameter values are
+       0x00 and 0x01. All other values will return Invalid Parameters.
+
+       This command is available for BR/EDR, LE-only and also dual
+       mode controllers. For BR/EDR is changes the page scan setting
+       and for LE controllers it changes the advertising type. For
+       dual mode controllers it affects both settings.
+
+       For LE capable controllers the connectable setting takes affect
+       when advertising is enabled (peripheral) or when directed
+       advertising events are received (central).
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
@@ -204,9 +383,17 @@ Set Connectable Command
        When switching connectable off, it will expire a discoverable
        setting with a timeout.
 
+       This setting does not affect known devices from Add Device
+       command. These devices are always allowed to connect.
+
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Fast Connectable Command
 ============================
@@ -216,27 +403,53 @@ Set Fast Connectable Command
        Command Parameters:     Enable (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
-       This command can be used when the controller is not powered and
-       all settings will be programmed once powered.
+       This command is used to set the controller into a connectable
+       state where the page scan parameters have been set in a way to
+       favor faster connect times with the expense of higher power
+       consumption.
 
-       If connectable is not set, then this command will fail.
+       The allowed values of the Enable command parameter are 0x00 and
+       0x01. All other values will return Invalid Parameters.
+
+       This command is only available for BR/EDR capable controllers
+       (e.g. not for single-mode LE ones). It will return Not Supported
+       otherwise.
+
+       This command can only be used when the controller is powered on
+       and will return Not Powerd otherwise.
+
+       If connectable is not set, then this command will fail with
+       Rejected error.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Failed
+                               Busy
+                               Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
-Set Pairable Command
+Set Bondable Command
 ====================
 
        Command Code:           0x0009
        Controller Index:       <controller id>
-       Command Parameters:     Pairable (1 Octet)
+       Command Parameters:     Bondable (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to set the bondable property of an
+       controller. The allowed values for the Bondable command
+       parameter are 0x00 and 0x01. All other values will return
+       Invalid Parameters.
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
-       Turning pairable on will not automatically switch the controller
+       Turning bondable on will not automatically switch the controller
        into connectable mode. That needs to be done separately.
 
        The setting will be remembered during power down/up toggles.
@@ -244,6 +457,9 @@ Set Pairable Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Set Link Security Command
 =========================
@@ -253,12 +469,26 @@ Set Link Security Command
        Command Parameters:     Link_Security (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to either enable or disable link level
+       security for an controller (also known as Security Mode 3). The
+       allowed values for the Link_Security command parameter are 0x00
+       and 0x01. All other values will return Invalid Parameters.
+
+       This command is only available for BR/EDR capable controllers
+       (e.g. not for single-mode LE ones). It will return Not Supported
+       otherwise.
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Secure Simple Pairing Command
 =================================
@@ -268,15 +498,28 @@ Set Secure Simple Pairing Command
        Command Parameters:     Secure_Simple_Pairing (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to enable/disable Secure Simple Pairing
+       support for a controller. The allowed values for the
+       Secure_Simple_Pairing command parameter are 0x00 and 0x01. All
+       other values will return Invalid Parameters.
+
+       This command is only available for BR/EDR capable controllers
+       supporting the core specification version 2.1 or greater
+       (e.g. not for single-mode LE controllers or pre-2.1 ones).
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
        In case the controller does not support Secure Simple Pairing,
-       the command will fail regardless.
+       the command will fail regardless with Not Supported error.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
 
 Set High Speed Command
 ======================
@@ -286,15 +529,33 @@ Set High Speed Command
        Command Parameters:     High_Speed (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to enable/disable Bluetooth High Speed
+       support for a controller. The allowed values for the High_Speed
+       command parameter are 0x00 and 0x01. All other values will
+       return Invalid Parameters.
+
+       This command is only available for BR/EDR capable controllers
+       (e.g. not for single-mode LE ones).
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
-       In case the kernel subsystem does not support High Speed, the
-       command will fail regardless.
+       To enable High Speed support, it is required that Secure Simple
+       Pairing support is enabled first. High Speed support is not
+       possible for connections without Secure Simple Pairing.
+
+       When switching Secure Simple Pairing off, the support for High
+       Speed will be switched off as well. Switching Secure Simple
+       Pairing back on, will not re-enable High Speed support. That
+       needs to be done manually.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Low Energy Command
 ======================
@@ -304,6 +565,14 @@ Set Low Energy Command
        Command Parameters:     Low_Energy (1 Octet)
        Return Parameters:      Current_Settings (4 Octets)
 
+       This command is used to enable/disable Low Energy support for a
+       controller. The allowed values of the Low_Energy command
+       parameter are 0x00 and 0x01. All other values will return
+       Invalid Parameters.
+
+       This command is only available for LE capable controllers and
+       will yield in a Not Supported error otherwise.
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
@@ -313,6 +582,11 @@ Set Low Energy Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Device Class
 ================
@@ -323,9 +597,15 @@ Set Device Class
                                Minor_Class (1 Octet)
        Return Parameters:      Class_Of_Device (3 Octets)
 
+       This command is used to set the major and minor device class for
+       BR/EDR capable controllers.
+
        This command will also implicitly disable caching of pending CoD
        and EIR updates.
 
+       This command is only available for BR/EDR capable controllers
+       (e.g. not for single-mode LE ones).
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
@@ -336,6 +616,11 @@ Set Device Class
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
 
 Set Local Name Command
 ======================
@@ -347,6 +632,10 @@ Set Local Name Command
        Return Parameters:      Name (249 Octets)
                                Short_Name (11 Octets)
 
+       This command is used to set the local name of a controller. The
+       command parameters also include a short name which will be used
+       in case the full name doesn't fit within EIR/AD data.
+
        The name parameters need to always end with a null byte (failure
        to do so will cause the command to fail).
 
@@ -361,6 +650,9 @@ Set Local Name Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Add UUID Command
 ================
@@ -371,6 +663,11 @@ Add UUID Command
                                SVC_Hint (1 Octet)
        Return Parameters:      Class_Of_Device (3 Octets)
 
+       This command is used to add a UUID to be published in EIR data.
+       The accompanied SVC_Hint parameter is used to tell the kernel
+       whether the service class bits of the Class of Device value need
+       modifying due to this UUID.
+
        This command can be used when the controller is not powered and
        all settings will be programmed once powered.
 
@@ -381,6 +678,10 @@ Add UUID Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Invalid Parameters
+                               Invalid Index
+
 
 Remove UUID Command
 ===================
@@ -390,6 +691,9 @@ Remove UUID Command
        Command Parameters:     UUID (16 Octets)
        Return Parameters:      Class_Of_Device (3 Octets)
 
+       This command is used to remove a UUID previously added using the
+       Add UUID command.
+
        When the UUID parameter is an empty UUID (16 x 0x00), then all
        previously loaded UUIDs will be removed.
 
@@ -403,6 +707,10 @@ Remove UUID Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Busy
+                               Invalid Parameters
+                               Invalid Index
+
 
 Load Link Keys Command
 ======================
@@ -422,36 +730,99 @@ Load Link Keys Command
                                ...
        Return Parameters:
 
+       This command is used to feed the kernel with currently known
+       link keys. The command does not need to be called again upon the
+       receiption of New Link Key events since the kernel updates its
+       list automatically.
+
+       The Debug_Keys parameter is used to tell the kernel whether to
+       accept the usage of debug keys or not. The allowed values for
+       this parameter are 0x00 and 0x01. All other values will return
+       an Invalid Parameters response.
+
+       Usage of the Debug_Keys parameter is deprecated and has been
+       replaced with the Set Debug Keys command. When setting the
+       Debug_Keys option via Load Link Keys command it has the same
+       affect as setting it via Set Debug Keys and applies to all
+       keys in the system.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       Reserved (not in use)
+               2       Reserved (not in use)
+
+       Public and random LE addresses are not valid and will be rejected.
+
+       Currently defined Key_Type values are:
+
+               0x00    Combination key
+               0x01    Local Unit key
+               0x02    Remote Unit key
+               0x03    Debug Combination key
+               0x04    Unauthenticated Combination key from P-192
+               0x05    Authenticated Combination key from P-192
+               0x06    Changed Combination key
+               0x07    Unauthenticated Combination key from P-256
+               0x08    Authenticated Combination key from P-256
+
        This command can be used when the controller is not powered.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Load Long Term Keys Command
 ===========================
 
        Command Code:           0x0013
        Controller Index:       <controller id>
-       Command Parameters:     Key Count (2 Octets)
+       Command Parameters:     Key_Count (2 Octets)
                                Key1 {
                                        Address (6 Octets)
                                        Address_Type (1 Octet)
-                                       Authenticated (1 Octet)
+                                       Key_Type (1 Octet)
                                        Master (1 Octet)
-                                       Encryption Size (1 Octet)
-                                       EncDiversifier (2 Octets)
-                                       Random Number (8 Octets)
+                                       Encryption_Size (1 Octet)
+                                       Encryption_Diversifier (2 Octets)
+                                       Random_Number (8 Octets)
                                        Value (16 Octets)
                                }
                                Key2 {  }
                                ...
+       Return Parameters:
+
+       This command is used to feed the kernel with currently known
+       (SMP) Long Term Keys. The command does not need to be called
+       again upon the receiption of New Long Term Key events since the
+       kernel updates its list automatically.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
+
+       Unresolvable random addresses and resolvable random addresses are
+       not valid and will be rejected.
+
+       Currently defined Key_Type values are:
+
+               0x00    Unauthenticated key
+               0x01    Authenticated key
 
        This command can be used when the controller is not powered.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Disconnect Command
 ==================
@@ -463,11 +834,25 @@ Disconnect Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to force the disconnection of a currently
+       connected device.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Busy
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Get Connections Command
 =======================
@@ -483,16 +868,27 @@ Get Connections Command
                                Address2 { }
                                ...
 
+       This command is used to retreive a list of currently connected
+       devices.
+
        Possible values for the Address_Type parameter:
                0       BR/EDR
                1       LE Public
                2       LE Random
 
+       For devices using resolvable random addresses with a known
+       identity resolving key, the Address and Address_Type will
+       contain the identity information.
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 PIN Code Reply Command
 =======================
@@ -506,11 +902,23 @@ PIN Code Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to respond to a PIN Code request event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 PIN Code Negative Reply Command
 ===============================
@@ -522,11 +930,24 @@ PIN Code Negative Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to return a negative response to a PIN Code
+       Request event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Set IO Capability Command
 =========================
@@ -536,11 +957,28 @@ Set IO Capability Command
        Command Parameters:     IO_Capability (1 Octet)
        Return Parameters:
 
+       This command is used to set the IO Capability used for pairing.
+       The command accepts both SSP and SMP values.
+
+       Possible values for the IO_Capability parameter:
+               0       DisplayOnly
+               1       DisplayYesNo
+               2       KeyboardOnly
+               3       NoInputNoOutput
+               4       KeyboardDisplay
+
+       Passing a value 4 (KeyboardDisplay) will cause the kernel to
+       convert it to 1 (DisplayYesNo) in the case of a BR/EDR
+       connection (as KeyboardDisplay is specific to SMP).
+
        This command can be used when the controller is not powered.
 
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Pair Device Command
 ===================
@@ -553,19 +991,59 @@ Pair Device Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to trigger pairing with a remote device.
+       The IO_Capability command parameter is used to temporarily (for
+       this pairing event only) override the global IO Capaility (set
+       using the Set IO Capability command).
+
        Possible values for the Address_Type parameter:
                0       BR/EDR
                1       LE Public
                2       LE Random
 
+       Possible values for the IO_Capability parameter:
+               0       DisplayOnly
+               1       DisplayYesNo
+               2       KeyboardOnly
+               3       NoInputNoOutput
+               4       KeyboardDisplay
+
+       Passing a value 4 (KeyboardDisplay) will cause the kernel to
+       convert it to 1 (DisplayYesNo) in the case of a BR/EDR
+       connection (as KeyboardDisplay is specific to SMP).
+
+       The Address and Address_Type of the return parameters will
+       return the identity address if known. In case of resolvable
+       random address given as command parameters and the remote
+       provides an identity resolving key, the return parameters
+       will provide the resolved address.
+
+       To allow tracking of which resolvable random address changed
+       into which identity address, the New Identity Resolving Key
+       event will be send before receiving Command Complete event
+       for this command.
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Reject status is used when requested transport is not enabled.
 
-Cancel Pair Device
-==================
+       Not Supported status is used if controller is not capable with
+       requested transport.
+
+       Possible errors:        Rejected
+                               Not Supported
+                               Connect Failed
+                               Busy
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
+
+Cancel Pair Device Command
+==========================
 
        Command Code:           0x001A
        Controller Index:       <controller id>
@@ -577,11 +1055,20 @@ Cancel Pair Device
        The Address and Address_Type parameters should match what was
        given to a preceding Pair Device command.
 
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Unpair Device Command
 =====================
@@ -596,16 +1083,34 @@ Unpair Device Command
 
        Removes all keys associated with the remote device.
 
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        The Disconnect parameter tells the kernel whether to forcefully
        disconnect any existing connections to the device. It should in
        practice always be 1 except for some special GAP qualification
        test-cases where a key removal without disconnecting is needed.
 
+       When unpairing a device its link key, long term key and if
+       provided identity resolving key will be purged.
+
+       For devices using resolvable random addresses where the identity
+       resolving key was available, after this command they will now no
+       longer be resolved. The device will essentially become private
+       again.
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Paired
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 User Confirmation Reply Command
 ===============================
@@ -617,11 +1122,24 @@ User Confirmation Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to respond to a User Confirmation Request
+       event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 User Confirmation Negative Reply Command
 ========================================
@@ -633,11 +1151,24 @@ User Confirmation Negative Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to return a negative response to a User
+       Confirmation Request event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 User Passkey Reply Command
 ==========================
@@ -650,11 +1181,24 @@ User Passkey Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to respond to a User Confirmation Passkey
+       Request event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 User Passkey Negative Reply Command
 ===================================
@@ -666,11 +1210,24 @@ User Passkey Negative Reply Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to return a negative response to a User
+       Passkey Request event.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Not Connected
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Read Local Out Of Band Data Command
 ===================================
@@ -678,14 +1235,32 @@ Read Local Out Of Band Data Command
        Command Code:           0x0020
        Controller Index:       <controller id>
        Command Parameters:
-       Return Parameters:      Hash (16 Octets)
-                               Randomizer (16 Octets)
+       Return Parameters:      Hash_192 (16 Octets)
+                               Randomizer_192 (16 Octets)
+                               Hash_256 (16 Octets, Optional)
+                               Randomizer_256 (16 Octets, Optional)
+
+       This command is used to read the local Out of Band data.
 
        This command can only be used when the controller is powered.
 
+       If Secure Connections support is enabled, then this command
+       will return P-192 versions of hash and randomizer as well as
+       P-256 versions of both.
+
+       Values returned by this command become invalid when the controller
+       is powered down. After each power-cycle it is required to call
+       this command again to get updated values.
+
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Not Supported
+                               Busy
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Add Remote Out Of Band Data Command
 ===================================
@@ -694,16 +1269,62 @@ Add Remote Out Of Band Data Command
        Controller Index:       <controller id>
        Command Parameters:     Address (6 Octets)
                                Address_Type (1 Octet)
-                               Hash (16 Octets)
-                               Randomizer (16 Octets)
+                               Hash_192 (16 Octets)
+                               Randomizer_192 (16 Octets)
+                               Hash_256 (16 Octets, Optional)
+                               Randomizer_256 (16 Octets, Optional)
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
-       This command can only be used when the controller is powered.
+       This command is used to provide Out of Band data for a remote
+       device.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       Provided Out Of Band data is persistent over power down/up toggles.
+
+       This command also accept optional P-256 versions of hash and
+       randomizer. If they are not provided, then they are set to
+       zero value.
+
+       The P-256 versions of both can also be provided when the
+       support for Secure Connections is not enabled. However in
+       that case they will never be used.
+
+       To only provide the P-256 versions of hash and randomizer,
+       it is valid to leave both P-192 fields as zero values. If
+       Secure Connections is disabled, then of course this is the
+       same as not providing any data at all.
+
+       When providing data for remote LE devices, then the Hash_192 field
+       is used to provide the Security Manager TK Value. The Randomizer_192
+       field is not used and shall be set to zero. The Hash_192 value can
+       also be set to zero and that means that no Out Of Band data for
+       LE legacy pairing is provided.
+
+       The Hash_256 and Randomizer_256 fields can be used for LE secure
+       connections Out Of Band data. If only LE secure connections data
+       is provided the Hash_P192 and Randomizer_P192 fields can be set
+       to zero.
+
+       If Secure Connections Only mode has been enabled, then providing
+       Hash_P192 and Randomizer_P192 is not allowed. They are required
+       to be set to zero values.
+
+       This command can be used when the controller is not powered and
+       all settings will be programmed once powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Failed
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Remove Remote Out Of Band Data Command
 ======================================
@@ -715,11 +1336,27 @@ Remove Remote Out Of Band Data Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
-       This command can only be used when the controller is powered.
+       This command is used to remove data added using the Add Remote
+       Out Of Band Data command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       When the Address parameter is 00:00:00:00:00:00, then all
+       previously added data will be removed.
+
+       This command can be used when the controller is not powered and
+       all settings will be programmed once powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Start Discovery Command
 =======================
@@ -729,12 +1366,16 @@ Start Discovery Command
        Command Parameters:     Address_Type (1 Octet)
        Return Parameters:      Address_Type (1 Octet)
 
+       This command is used to start the process of discovering remote
+       devices. A Device Found event will be sent for each discovered
+       device.
+
        Possible values for the Address_Type parameter are a bit-wise or
        of the following bits:
 
-               1       BR/EDR
-               2       LE Public
-               3       LE Random
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
 
        By combining these e.g. the following values are possible:
 
@@ -747,6 +1388,12 @@ Start Discovery Command
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
 
 Stop Discovery Command
 ======================
@@ -756,11 +1403,18 @@ Stop Discovery Command
        Command Parameters:     Address_Type (1 Octet)
        Return Parameters:      Address_Type (1 Octet)
 
+       This command is used to stop the discovery process started using
+       the Start Discovery command.
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Rejected
+                               Invalid Parameters
+                               Invalid Index
+
 
 Confirm Name Command
 ====================
@@ -777,11 +1431,25 @@ Confirm Name Command
        expected for each Device Found event with the Confirm Name
        flag set.
 
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The Name_Known parameter should be set to 0x01 if user space
+       knows the name for the device and 0x00 if it doesn't. If set to
+       0x00 the kernel will perform a name resolving procedure for the
+       device in question.
+
        This command can only be used when the controller is powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Failed
+                               Invalid Parameters
+                               Invalid Index
+
 
 Block Device Command
 ====================
@@ -793,11 +1461,33 @@ Block Device Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to add a device to the list of devices
+       which should be blocked from being connect to the local
+       controller.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       For Low Energy devices, the blocking of a device take presedence
+       over auto-connection actions provided by Add Device. Blocked
+       devices will not be auto-connected or even reported when found
+       during background scanning. If the controller is connectable
+       direct advertising from blocked devices will also be ignored.
+
+       Connections created from advertising of the controller will
+       be dropped if the device is blocked.
+
        This command can be used when the controller is not powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Failed
+                               Invalid Parameters
+                               Invalid Index
+
 
 Unblock Device Command
 ======================
@@ -809,11 +1499,25 @@ Unblock Device Command
        Return Parameters:      Address (6 Octets)
                                Address_Type (1 Octet)
 
+       This command is used to remove a device from the list of blocked
+       devices (where it was added to using the Block Device command).
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       When the Address parameter is 00:00:00:00:00:00, then all
+       previously blocked devices will be unblocked.
+
        This command can be used when the controller is not powered.
 
        This command generates a Command Complete event on success
        or failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
 
 Set Device ID Command
 =====================
@@ -844,165 +1548,1215 @@ Set Device ID Command
        This command generates a Command Complete event on success or
        a Command Status event on failure.
 
+       Possible errors:        Invalid Parameters
+                               Invalid Index
 
-Command Complete Event
-======================
 
-Event Code             0x0001
-Controller Index:      <controller id> or <non-controller>
-Event Parameters       Command_Opcode (2 Octets)
-                       Status (1 Octet)
-                       Return_Parameters
+Set Advertising Command
+=======================
 
+       Command Code:           0x0029
+       Controller Index:       <controller id>
+       Command Parameters:     Advertising (1 Octet)
+       Return Parameters:      Current_Settings (4 Octets)
 
-Command Status Event
-====================
+       This command is used to enable LE advertising on a controller
+       that supports it. The allowed values for the Advertising
+       command parameter are 0x00 and 0x01. All other values will
+       return Invalid Parameters.
 
-Event Code             0x0002
-Controller Index:      <controller id> or <non-controller>
-Event Parameters       Command_Opcode (2 Octets)
-                       Status (1 Octet)
+       A pre-requisite is that LE is already enabled, otherwise
+       this command will return a "rejected" response.
 
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
 
-Controller Error Event
-======================
+       Possible errors:        Busy
+                               Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
 
-Event Code             0x0003
-Controller Index:      <controller id>
-Event Parameters       Error_Code (1 Octet)
 
+Set BR/EDR Command
+==================
 
-Index Added Event
-=================
+       Command Code:           0x002A
+       Controller Index:       <controller id>
+       Command Parameters:     BR/EDR (1 Octet)
+       Return Parameters:      Current_Settings (4 Octets)
 
-Event Code             0x0004
-Controller Index:      <controller id>
-Event Parameters
+       This command is used to enable or disable BR/EDR support
+       on a dual-mode controller. The allowed values for the Advertising
+       command parameter are 0x00 and 0x01. All other values will
+       return Invalid Parameters.
 
+       A pre-requisite is that LE is already enabled, otherwise
+       this command will return a "rejected" response. Enabling BR/EDR
+       can be done both when powered on and powered off, however
+       disabling it can only be done when powered off (otherwise the
+       command will again return "rejected"). Disabling BR/EDR will
+       automatically disable all other BR/EDR related settings.
 
-Index Removed Event
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
+
+       Possible errors:        Busy
+                               Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Static Address Command
+==========================
+
+       Command Code:           0x002B
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+       Return Parameters:      Current_Settings (4 Octets)
+
+       This command allows for setting the static random address. It is
+       only supported on controllers with LE support. The static random
+       address is suppose to be valid for the lifetime of the
+       controller or at least until the next power cycle. To ensure
+       such behavior, setting of the address is limited to when the
+       controller is powered off.
+
+       The special BDADDR_ANY address (00:00:00:00:00:00) can be used
+       to disable the static address.
+
+       When a controller has a public address (which is required for
+       all dual-mode controllers), this address is not used. If a dual-mode
+       controller is configured as Low Energy only devices (BR/EDR has
+       been switched off), then the static address is used. Only when
+       the controller information reports BDADDR_ANY (00:00:00:00:00:00),
+       it is required to configure a static address first.
+
+       If privacy mode is enabled and the controller is single mode
+       LE only without a public address, the static random address is
+       used as identity address.
+
+       The Static Address flag from the current settings can also be used
+       to determine if the configured static address is in use or not.
+
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
+
+       Possible errors:        Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Scan Parameters Command
+===========================
+
+       Command Code:           0x002C
+       Controller Index:       <controller id>
+       Command Parameters:     Interval (2 Octets)
+                               Window (2 Octets)
+       Return Parameters:
+
+       This command allows for setting the Low Energy scan parameters
+       used for connection establishment and passive scanning. It is
+       only supported on controllers with LE support.
+
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
+
+       Possible errors:        Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Secure Connections Command
+==============================
+
+       Command Code:           0x002D
+       Controller Index:       <controller id>
+       Command Parameters:     Secure_Connections (1 Octet)
+       Return Parameters:      Current_Settings (4 Octets)
+
+       This command is used to enable/disable Secure Connections
+       support for a controller. The allowed values for the
+       Secure_Connections command parameter are 0x00, 0x01 and 0x02.
+       All other values will return Invalid Parameters.
+
+       The value 0x00 disables Secure Connections, the value 0x01
+       enables Secure Connections and the value 0x02 enables Secure
+       Connections Only mode.
+
+       This command is only available for LE capable controllers as
+       well as controllers supporting the core specification version
+       4.1 or greater.
+
+       This command can be used when the controller is not powered and
+       all settings will be programmed once powered.
+
+       In case the controller does not support Secure Connections
+       the command will fail regardless with Not Supported error.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Debug Keys Command
+======================
+
+       Command Code:           0x002E
+       Controller Index:       <controller id>
+       Command Parameters:     Debug_Keys (1 Octet)
+       Return Parameters:      Current_Settings (4 Octets)
+
+       This command is used to tell the kernel whether to accept the
+       usage of debug keys or not. The allowed values for this parameter
+       are 0x00, 0x01 and 0x02. All other values will return an Invalid
+       Parameters response.
+
+       With a value of 0x00 any generated debug key will be discarded
+       as soon as the connection terminates.
+
+       With a value of 0x01 generated debug keys will be kept and can
+       be used for future connections. However debug keys are always
+       marked as non persistent and should not be stored. This means
+       a reboot or changing the value back to 0x00 will delete them.
+
+       With a value of 0x02 generated debug keys will be kept and can
+       be used for future connections. This has the same affect as
+       with value 0x01. However in addition this value will also
+       enter the controller mode to generate debug keys for each
+       new pairing. Changing the value back to 0x01 or 0x00 will
+       disable the controller mode for generating debug keys.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Privacy Command
+===================
+
+       Command Code:           0x002F
+       Controller Index:       <controller id>
+       Command Parameters:     Privacy (1 Octet)
+                               Identity_Resolving_Key (16 Octets)
+       Return Parameters:      Current_Settings (4 Octets)
+
+       This command is used to enable Low Energy Privacy feature using
+       resolvable private addresses.
+
+       The value 0x00 disables privacy mode, the values 0x01 and 0x02
+       enable privacy mode.
+
+       With value 0x01 the kernel will always use the privacy mode. This
+       means resolvable private address is used when the controller is
+       discoverable and also when pairing is initiated.
+
+       With value 0x02 the kernel will use privacy mode with resolvable
+       private address. In case the conroller is bondable and discoverable
+       the identity address is used. Also when pairing is initiated, the
+       connection will be established with the identity address.
+
+       Exposing the identity address when bondable and discoverable or
+       during initated pairing can be a privacy issue. For dual-mode
+       controllers this can be neglected since its public address will
+       be exposed over BR/EDR anyway. The benefit of exposing the
+       identity address for pairing purposes is that it makes matching
+       up devices with dual-mode topology during device discovery now
+       possible.
+
+       If the privacy value 0x02 is used, then also the GATT database
+       should expose the Privacy Characteristic so that remote devices
+       can determine if the privacy feature is in use or not.
+
+       When the controller has a public address (mandatory for dual-mode
+       controllers) it is used as identity address. In case the controller
+       is single mode LE only without a public address, it is required
+       to configure a static random andress first. The privacy mode can
+       only be enabled when an identity address is available.
+
+       The Identity_Resolving_Key is the local key assigned for the local
+       resolvable private address.
+
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Load Identity Resolving Keys Command
+====================================
+
+       Command Code:           0x0030
+       Controller Index:       <controller id>
+       Command Parameters:     Key_Count (2 Octets)
+                               Key1 {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Value (16 Octets)
+                               }
+                               Key2 {  }
+                               ...
+       Return Parameters:
+
+       This command is used to feed the kernel with currently known
+       identity resolving keys. The command does not need to be called
+       again upon the receiption of New Identity Resolving Key events
+       since the kernel updates its list automatically.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
+
+       Unresolvable random addresses and resolvable random addresses are
+       not valid and will be rejected.
+
+       This command can be used when the controller is not powered.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
+#ifdef __TIZEN_PATCH__
+Generate Identity Resolving Key Command
+=======================================
+
+       Command Code:           0x00F6
+       Controller Index:       <controller id>
+       Command Parameters:
+       Return Parameters:
+
+       This command is used to generate identity resolving key for the
+       local device, which will be used at the time of pairing for key
+       distribution and to     generate resolvable private address for local device.
+
+       This command generates a Command Complete event on success
+       or a Command Status event on failure.
+
+       Possible errors:        Failed
+                               Invalid Index
+
+Generate Resolvable Private Address Command
+=======================================
+
+       Command Code:           0x00F5
+       Controller Index:       <controller id>
+       Command Parameters:
+       Return Parameters:      Resolvable Private Address (6 Octets)
+
+       This command is used to generate resolvable private address for the
+       local device when LE privacy is supported and device is having its IRK.
+
+       This command returns generated private address which is resolvable
+       by remote device on success.
+
+       This command generates a Command Complete event on success
+       or a Command Status event on failure.
+
+       Possible errors:        Failed
+                               Invalid Index
+
+Set Random Address Command
+==========================
+
+       Command Code:           0x00F4
+       Controller Index:       <controller id>
+       Command Parameters:     Resolvable Private Address (6 Octets)
+       Return Parameters:
+
+       This command is used to set the random address to local controller.
+       If local device supports LE Privacy then this command will be called to set
+       its Random address while active scanning remote devices and in the case of
+       advertising itself.
+
+       This command intern calls the HCI Set Random address command from kernel
+       space to set the RPA to controller.
+
+       This command generates a Command Complete event on success
+       or a Command Status event on failure.
+
+       Possible errors:        Failed
+                               Invalid Index
+
+#endif
+
+Get Connection Information Command
+==================================
+
+       Command Code:           0x0031
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+                               Address_Type (1 Octet)
+       Return Parameters:      Address (6 Octets)
+                               Address_Type (1 Octet)
+                               RSSI (1 Octet)
+                               TX_Power (1 Octet)
+                               Max_TX_Power (1 Octet)
+
+       This command is used to get connection information.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       TX_Power and Max_TX_Power can be set to 127 if values are invalid or
+       unknown. A value of 127 for RSSI indicates that it is not available.
+
+       This command generates a Command Complete event on success and
+       on failure. In case of failure only Address and Address_Type fields
+       are valid and values of remaining parameters are considered invalid
+       and shall be ignored.
+
+       Possible errors:        Not Connected
+                               Not Powered
+                               Invalid Parameters
+                               Invalid Index
+
+
+Get Clock Information Command
+=============================
+
+       Command Code:           0x0032
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+                               Address_Type (1 Octet)
+       Return Parameters:      Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Local_Clock (4 Octets)
+                               Piconet_Clock (4 Octets)
+                               Accuracy (2 Octets)
+
+       This command is used to get local and piconet clock information.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       Reserved (not in use)
+               2       Reserved (not in use)
+
+       The Accuracy can be set to 0xffff which means the value is unknown.
+
+       If the Address is set to 00:00:00:00:00:00, then only the
+       Local_Clock field has a valid value. The Piconet_Clock and
+       Accuracy fields are invalid and shall be ignored.
+
+       This command generates a Command Complete event on success and
+       on failure. In case of failure only Address and Address_Type fields
+       are valid and values of remaining parameters are considered invalid
+       and shall be ignored.
+
+       Possible errors:        Not Connected
+                               Not Powered
+                               Invalid Parameters
+                               Invalid Index
+
+
+Add Device Command
+==================
+
+       Command Code:           0x0033
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Action (1 Octet)
+       Return Parameters:      Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This command is used to add a device to the action list. The
+       action list allows scanning for devices and enables incoming
+       connections from known devices.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       Possible values for the Action parameter:
+               0       Background scan for device
+               1       Allow incoming connection
+               2       Auto-connect remote device
+
+       With the Action 0, when the device is found, a new Device Found
+       event will be send indicating this device is available. This
+       action is only valid for LE Public and LE Random address types.
+
+       With the Action 1, the device is allowed to connect. For BR/EDR
+       address type this means an incoming connection. For LE Public
+       and LE Random address types, a connection will be established
+       to devices using directed advertising. If successful a Device
+       Connected event will be send.
+
+       With the Action 2, when the device is found, it will be connected
+       and if successful a Device Connected event will be send. This
+       action is only valid for LE Public and LE Random address types.
+
+       When a device is blocked using Block Device command, then it is
+       valid to add the device here, but all actions will be ignored
+       until the device is unblocked.
+
+       Devices added with Action 1 are allowed to connect even if the
+       connectable setting is off. This acts as list of known trusted
+       devices.
+
+       This command can be used when the controller is not powered and
+       all settings will be programmed once powered.
+
+       This command generates a Command Complete event on success
+       or failure.
+
+       Possible errors:        Failed
+                               Invalid Parameters
+                               Invalid Index
+
+
+Remove Device Command
+=====================
+
+       Command Code:           0x0034
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+                               Address_Type (1 Octet)
+       Return Parameters:      Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This command is used to remove a device from the action list
+       previously added by using the Add Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       When the Address parameter is 00:00:00:00:00:00, then all
+       previously added devices will be removed.
+
+       This command can be used when the controller is not powered and
+       all settings will be programmed once powered.
+
+       This command generates a Command Complete event on success
+       or failure.
+
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
+
+Load Connection Parameters Command
+==================================
+
+       Command Code:           0x0035
+       Controller Index:       <controller id>
+       Command Parameters:     Param_Count (2 Octets)
+                               Param1 {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Min_Connection_Interval (2 Octets)
+                                       Max_Connection_Interval (2 Octes)
+                                       Connection_Latency (2 Octets)
+                                       Supervision_Timeout (2 Octets)
+                               }
+                               Param2 {  }
+                               ...
+       Return Parameters:
+
+       This command is used to load connection parameters from several
+       devices into kernel. Currently this is only supported on controllers
+       with Low Energy support.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
+
+       The Min_Connection_Interval, Max_Connection_Interval,
+       Connection_Latency and Supervision_Timeout parameters should
+       be configured as described in Core 4.1 spec, Vol 2, 7.8.12.
+
+       This command can be used when the controller is not powered.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+                               Not Supported
+
+
+Read Unconfigured Controller Index List Command
+===============================================
+
+       Command Code:           0x0036
+       Controller Index:       <non-controller>
+       Command Parameters:
+       Return Parameters:      Num_Controllers (2 Octets)
+                               Controller_Index[i] (2 Octets)
+
+       This command returns the list of currently unconfigured controllers.
+       Unconfigured controllers added after calling this command can be
+       monitored using the Unconfigured Index Added event.
+
+       An unconfigured controller can either move to a configured state
+       by indicating Unconfigured Index Removed event followed by an
+       Index Added event; or it can be removed from the system which
+       would be indicated by the Unconfigured Index Removed event.
+
+       Only controllers that require configuration will be listed with
+       this command. A controller that is fully configured will not
+       be listed even if it supports configuration changes.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+
+Read Controller Configuration Information Command
+=================================================
+
+       Command Code:           0x0037
+       Controller Index:       <controller id>
+       Command Parameters:
+       Return Parameters:      Manufacturer (2 Octets)
+                               Supported_Options (4 Octets)
+                               Missing_Options (4 Octets)
+
+       This command is used to retreive the supported configuration
+       options of a controller and the missing configuration options.
+
+       The missing options are required to be configured before the
+       controller is considered fully configured and ready for standard
+       operation. The command is typically used right after getting the
+       response to Read Unconfigured Controller Index List command or
+       Unconfigured Index Added event.
+
+       Supported_Options and Missing_Options is a bitmask with currently
+       the following available bits:
+
+               0       External configuration
+               1       Bluetooth public address configuration
+
+       It is valid to call this command on controllers that do not
+       require any configuration. It is possible that a fully configured
+       controller offers additional support for configuration.
+
+       For example a controller may contain a valid Bluetooth public
+       device address, but also allows to configure it from the host
+       stack. In this case the general support for configurations will
+       be indicated by the Controller Configuration settings. For
+       controllers where no configuration options are available that
+       setting option will not be present.
+
+       When all configurations have been completed and as a result the
+       Missing_Options mask would become empty, then the now ready
+       controller will be announced via Index Added event.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Invalid Parameters
+                               Invalid Index
+
+
+Set External Configuration Command
+==================================
+
+       Command Code:           0x0038
+       Controller Index:       <controller id>
+       Command Parameters:     Configuration (1 Octet)
+       Return Parameters:      Missing_Options (4 Octets)
+
+       This command allows to change external configuration option to
+       indicate that a controller is now configured or unconfigured.
+
+       The value 0x00 sets unconfigured state and the value 0x01 sets
+       configured state of the controller.
+
+       It is not mandatory that this configuration option is provided
+       by a controller. If it is provided, the configuration has to
+       happen externally using user channel operation or via vendor
+       specific methods.
+
+       Setting this option and when Missing_Options returns zero, this
+       means that the controller will switch to configured state and it
+       can be expected that it will be announced via Index Added event.
+
+       Wrongly configured controllers might still cause an error when
+       trying to power them via Set Powered commmand.
+
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
+
+       Possible errors:        Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Set Public Address Command
+==========================
+
+       Command Code:           0x0039
+       Controller Index:       <controller id>
+       Command Parameters:     Address (6 Octets)
+       Return Parameters:      Missing_Options (4 Octets)
+
+       This command allows configuration of public address. Since a vendor
+       specific procedure is required, this command might not be supported
+       by all controllers. Actually most likely only a handful embedded
+       controllers will offer support for this command.
+
+       When the support for Bluetooth public address configuration is
+       indicated in the supported options mask, then this command
+       can be used to configure the public address.
+
+       It is only possible to configure the public address when the
+       controller is powered off.
+
+       For an unconfigured controller and when Missing_Options returns
+       an empty mask, this means that a Index Added event for the now
+       fully configured controller can be expected.
+
+       For a fully configured controller, the current controller index
+       will become invalid and an Unconfigured Index Removed event will
+       be send. Once the address has been successfully changed an Index
+       Added event will be send. There is no guarantee that the controller
+       index stays the same.
+
+       All previous configured parameters and settings are lost when
+       this command succeeds. The controller has to be treated as new
+       one. Use this command for a fully configured controller only when
+       you really know what you are doing.
+
+       This command generates a Command Complete event on success or a
+       Command Status event on failure.
+
+       Possible errors:        Rejected
+                               Not Supported
+                               Invalid Parameters
+                               Invalid Index
+
+
+Start Service Discovery Command
+===============================
+
+       Command Code:           0x003a
+       Controller Index:       <controller id>
+       Command Parameters:     Address_Type (1 Octet)
+                               RSSI_Threshold (1 Octet)
+                               UUID_Count (1 Octet)
+                               UUID[i] (16 Octets)
+       Return Parameters:      Address_Type (1 Octet)
+
+       This command is used to start the process of discovering remote
+       devices with a specific UUID. A Device Found event will be sent
+       for each discovered device.
+
+       Possible values for the Address_Type parameter are a bit-wise or
+       of the following bits:
+
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       By combining these e.g. the following values are possible:
+
+               1       BR/EDR
+               6       LE (public & random)
+               7       BR/EDR/LE (interleaved discovery)
+
+       The service discovery uses active scanning for Low Energy scanning
+       and will search for UUID in both advertising data and scan response
+       data.
+
+       Found devices that have a RSSI value smaller than RSSI_Threshold
+       are not reported via DeviceFound event. Setting a value of 127
+       will cause all devices to be reported.
+
+       The list of UUIDs identifies a logical OR. Only one of the UUIDs
+       have to match to cause a DeviceFound event. Providing an empty
+       list of UUIDs with Num_UUID set to 0 which means that DeviceFound
+       events are send out for all devices above the RSSI_Threshold.
+
+       In case RSSI_Threshold is set to 127 and UUID_Count is 0, then
+       this command behaves exactly the same as Start Discovery.
+
+       When the discovery procedure starts the Discovery event will
+       notify this similar to Start Discovery.
+
+       This command can only be used when the controller is powered.
+
+       This command generates a Command Complete event on success
+       or failure.
+
+       Possible errors:        Busy
+                               Not Supported
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
+
+Read Local Out Of Band Extended Data Command
+============================================
+
+       Command Code:           0x003b
+       Controller Index:       <controller id>
+       Command Parameters:     Address_Type (1 Octet)
+       Return Parameters:      Address_Type (1 Octet)
+                               EIR_Data_Length (2 Octets)
+                               EIR_Data (0-65535 Octets)
+
+       This command is used to read the local Out of Band data
+       information and provide them encoded as extended inquiry
+       response information or advertising data.
+
+       Possible values for the Address_Type parameter are a bit-wise or
+       of the following bits:
+
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       By combining these e.g. the following values are possible:
+
+               1       BR/EDR
+               6       LE (public & random)
+               7       Reserved (not in use)
+
+       For BR/EDR controller (Address_Type 1) the returned information
+       will contain the following information:
+
+               Class of Device
+               Simple Pairing Hash C-192 (optional)
+               Simple Pairing Randomizer R-192 (optional)
+               Simple Pairing Hash C-256 (optional)
+               Simple Pairing Randomizer R-256 (optional)
+               Service Class UUID (optional)
+               Bluetooth Local Name (optional)
+
+       The Simple Pairing Hash C-256 and Simple Pairing Randomizer R-256
+       fields are only included when secure connections has been enabled.
+
+       The Device Address (BD_ADDR) is not included in the EIR_Data and
+       needs to be taken from controller information.
+
+       For LE controller (Address_Type 6) the returned information
+       will contain the following information:
+
+               LE Bluetooth Device Address
+               LE Role
+               Security Manager TK Value (optional)
+               LE Secure Connections Confirmation Value (optional)
+               LE Secure Connections Random Value (optional)
+               Appearance (optional)
+               Local Name (optional)
+               Flags
+
+       The LE Secure Connections Confirmation Value and LE Secure Connections
+       Random Value fields are only included when secure connections has been
+       enabled.
+
+       The returned information from BR/EDR controller and LE controller
+       types are not related to each other. Once they have been used
+       over an Out Of Band link, a new set of information shall be
+       requested.
+
+       When Secure Connections Only mode has been enabled, then the fields
+       for Simple Pairing Hash C-192, Simple Pairing Randomizer R-192 and
+       Security Manager TK Value are not returned. Only the fields for
+       the strong secure connections pairing are included.
+
+       This command can only be used when the controller is powered.
+
+       Values returned by this command become invalid when the controller
+       is powered down. After each power-cycle it is required to call
+       this command again to get updated information.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+       Possible errors:        Not Supported
+                               Busy
+                               Invalid Parameters
+                               Not Powered
+                               Invalid Index
+
+
+Read Extended Controller Index List Command
+===========================================
+
+       Command Code:           0x003c
+       Controller Index:       <non-controller>
+       Command Parameters:
+       Return Parameters:      Num_Controllers (2 Octets)
+                               Controller_Index[i] (2 Octets)
+                               Controller_Type[i] (1 Octet)
+
+       This command returns the list of currently known controllers. It
+       includes configured, unconfigured and alternate controllers.
+
+       Controllers added or removed after calling this command can be
+       be monitored using the Extended Index Added and Extended Index
+       Removed events.
+
+       The existing Index Added, Index Removed, Unconfigured Index Added
+       and Unconfigured Index Removed are no longer sent after this command
+       has been used at least once.
+
+       Instead of calling Read Controller Index List and Read Unconfigured
+       Controller Index List, this command combines all the information
+       and can be used to retrieve the controller list.
+
+       The Controller_Type parameter has these values:
+
+               0x00    Primary Controller (BR/EDR and/or LE)
+               0x01    Unconfigured Controller (BR/EDR and/or LE)
+               0x02    Alternate MAC/PHY Controller (AMP)
+
+       The 0x00 and 0x01 types indiciate a primary BR/EDR and/or LE
+       controller. The difference is just if they need extra configuration
+       or if they are fully configured.
+
+       Controllers in configured state will be listed as 0x00 and controllers
+       in unconfigured state will be listed as 0x01. A controller that is
+       fully configured and supports configuration changes will be listed
+       as 0x00.
+
+       Alternate MAC/PHY controllers will be listed as 0x02. They do not
+       support the difference between configured and unconfigured state.
+
+       Controllers marked as RAW only operation are currently not listed
+       by this command.
+
+       This command generates a Command Complete event on success or
+       a Command Status event on failure.
+
+
+Command Complete Event
+======================
+
+       Event Code:             0x0001
+       Controller Index:       <controller id> or <non-controller>
+       Event Parameters:       Command_Opcode (2 Octets)
+                               Status (1 Octet)
+                               Return_Parameters
+
+       This event is an indication that a command has completed. The
+       fixed set of parameters includes the opcode to identify the
+       command that completed as well as a status value to indicate
+       success or failure. The rest of the parameters are command
+       specific and documented in the section for each command
+       separately.
+
+
+Command Status Event
+====================
+
+       Event Code:             0x0002
+       Controller Index:       <controller id> or <non-controller>
+       Event Parameters:       Command_Opcode (2 Octets)
+                               Status (1 Octet)
+
+       The command status event is used to indicate an early status for
+       a pending command. In the case that the status indicates failure
+       (anything else except success status) this also means that the
+       command has finished executing.
+
+
+Controller Error Event
+======================
+
+       Event Code:             0x0003
+       Controller Index:       <controller id>
+       Event Parameters:       Error_Code (1 Octet)
+
+       This event maps straight to the HCI Hardware Error event and is
+       used to indicate something wrong with the controller hardware.
+
+
+Index Added Event
+=================
+
+       Event Code:             0x0004
+       Controller Index:       <controller id>
+       Event Parameters:
+
+       This event indicates that a new controller has been added to the
+       system. It is usually followed by a Read Controller Information
+       command.
+
+       Once the Read Extended Controller Index List command has been
+       used at least once, the Extended Index Added event will be
+       send instead of this one.
+
+
+Index Removed Event
 ===================
 
-Event Code             0x0005
-Controller Index:      <controller id>
-Event Parameters
+       Event Code:             0x0005
+       Controller Index:       <controller id>
+       Event Parameters:
+
+       This event indicates that a controller has been removed from the
+       system.
+
+       Once the Read Extended Controller Index List command has been
+       used at least once, the Extended Index Removed event will be
+       send instead of this one.
+
+
+New Settings Event
+==================
+
+       Event Code:             0x0006
+       Controller Index:       <controller id>
+       Event Parameters:       Current_Settings (4 Octets)
+
+       This event indicates that one or more of the settings for a
+       controller has changed.
+
+
+Class Of Device Changed Event
+=============================
+
+       Event Code:             0x0007
+       Controller Index:       <controller id>
+       Event Parameters:       Class_Of_Device (3 Octets)
+
+       This event indicates that the Class of Device value for the
+       controller has changed. When the controller is powered off the
+       Class of Device value will always be reported as zero.
+
+
+Local Name Changed Event
+========================
+
+       Event Code:             0x0008
+       Controller Index:       <controller id>
+       Event Parameters:       Name (249 Octets)
+                               Short_Name (11 Octets)
+
+       This event indicates that the local name of the controller has
+       changed.
+
+
+New Link Key Event
+==================
+
+       Event Code:             0x0009
+       Controller Index:       <controller id>
+       Event Parameters:       Store_Hint (1 Octet)
+                               Key {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Key_Type (1 Octet)
+                                       Value (16 Octets)
+                                       PIN_Length (1 Octet)
+                               }
+
+       This event indicates that a new link key has bee generated for a
+       remote device.
 
+       The Store_Hint parameter indicates whether the host is expected
+       to store the key persistently or not (e.g. this would not be set
+       if the authentication requirement was "No Bonding").
 
-New Settings Event
-==================
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       Reserved (not in use)
+               2       Reserved (not in use)
 
-Event Code             0x0006
-Controller Index:      <controller id>
-Event Parameters:      Current_Settings (4 Octets)
+       Public and random LE addresses are not valid and will be rejected.
 
+       Currently defined Key_Type values are:
 
-Class Of Device Changed Event
-=============================
+               0x00    Combination key
+               0x01    Local Unit key
+               0x02    Remote Unit key
+               0x03    Debug Combination key
+               0x04    Unauthenticated Combination key from P-192
+               0x05    Authenticated Combination key from P-192
+               0x06    Changed Combination key
+               0x07    Unauthenticated Combination key from P-256
+               0x08    Authenticated Combination key from P-256
 
-Event Code             0x0007
-Controller Index:      <controller id>
-Event Parameters:      Class_Of_Device (3 Octets)
+       Receiving this event indicates that a pairing procecure has
+       been completed.
 
 
-Local Name Changed Event
-========================
+New Long Term Key Event
+=======================
 
-Event Code             0x0008
-Controller Index       <controller id>
-Event Parameters       Name (249 Octets)
-                       Short_Name (11 Octets)
+       Event Code:             0x000A
+       Controller Index:       <controller id>
+       Event Parameters:       Store_Hint (1 Octet)
+                               Key {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Key_Type (1 Octet)
+                                       Master (1 Octet)
+                                       Encryption Size (1 Octet)
+                                       Enc. Diversifier (2 Octets)
+                                       Random Number (8 Octets)
+                                       Value (16 Octets)
+                               }
 
+       This event indicates that a new long term key has been generated
+       for a remote device.
 
-New Link Key Event
-==================
+       The Store_Hint parameter indicates whether the host is expected
+       to store the key persistently or not (e.g. this would not be set
+       if the authentication requirement was "No Bonding").
 
-Event Code             0x0009
-Controller Index:      <controller id>
-Event Parameters       Key {
-                               Address (6 Octets)
-                               Address_Type (1 Octet)
-                               Key_Type (1 Octet)
-                               Value (16 Octets)
-                               PIN_Length (1 Octet)
-                       }
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
 
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
 
-New Long Term Key Event
-=======================
+       For unresolvable random addresses and resolvable random addresses
+       without identity information and identity resolving key, the
+       Store_Hint will be set to not store the long term key.
 
-Event Code             0x000A
-Controller Index       <controller id>
-Event Parameters       Store Hint (1 Octet)
-                       Key {
-                               Address (6 Octets)
-                               Address_Type (1 Octet)
-                               Authenticated (1 Octet)
-                               Master (1 Octet)
-                               Encryption Size (1 Octet)
-                               Enc. Diversifier (2 Octets)
-                               Random Number (8 Octets)
-                               Value (16 Octets)
-                       }
+       Currently defined Key_Type values are:
+
+               0x00    Unauthenticated legacy key
+               0x01    Authenticated legacy key
+               0x02    Unauthenticated key from P-256
+               0x03    Authenticated key from P-256
+               0x04    Debug key from P-256
+
+       Receiving this event indicates that a pairing procecure has
+       been completed.
 
 
 Device Connected Event
 ======================
 
-Event Code             0x000B
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       Flags (4 Octets)
-                       EIR_Data_Length (2 Octets)
-                       EIR_Data (0-65535 Octets)
+       Event Code:             0x000B
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Flags (4 Octets)
+                               EIR_Data_Length (2 Octets)
+                               EIR_Data (0-65535 Octets)
+
+       This event indicates that a successful baseband connection has
+       been created to the remote device.
 
        Possible values for the Address_Type parameter:
                0       BR/EDR
                1       LE Public
                2       LE Random
 
+       For devices using resolvable random addresses with a known
+       identity resolving key, the Address and Address_Type will
+       contain the identity information.
+
+       It is possible that devices get connected via its resolvable
+       random address and after New Identity Resolving Key event
+       start using its identity.
+
        The following bits are defined for the Flags parameter:
                0       Reserved (not in use)
                1       Legacy Pairing
+               2       Reserved (not in use)
 
 
 Device Disconnected Event
 =========================
 
-Event Code             0x000C
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
+       Event Code:             0x000C
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Reason (1 Octet)
+
+       This event indicates that the baseband connection was lost to a
+       remote device.
 
        Possible values for the Address_Type parameter:
                0       BR/EDR
                1       LE Public
                2       LE Random
 
+       For devices using resolvable random addresses with a known
+       identity resolving key, the Address and Address_Type will
+       contain the identity information.
+
+       Possible values for the Reason parameter:
+               0       Unspecified
+               1       Connection timeout
+               2       Connection terminated by local host
+               3       Connection terminated by remote host
+
+       Note that the local/remote distinction just determines which side
+       terminated the low-level connection, regardless of the
+       disconnection of the higher-level profiles.
+
+       This can sometimes be misleading and thus must be used with care.
+       For example, some hardware combinations would report a locally
+       initiated disconnection even if the user turned Bluetooth off in
+       the remote side.
+
 
 Connect Failed Event
 ====================
 
-Event Code             0x000D
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       Status (1 Octet)
+       Event Code:             0x000D
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Status (1 Octet)
+
+       This event indicates that a connection attempt failed to a
+       remote device.
 
        Possible values for the Address_Type parameter:
                0       BR/EDR
                1       LE Public
                2       LE Random
 
+       For devices using resolvable random addresses with a known
+       identity resolving key, the Address and Address_Type will
+       contain the identity information.
+
 
 PIN Code Request Event
 ======================
 
-Event Code             0x000E
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       Secure (1 Octet)
+       Event Code:             0x000E
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Secure (1 Octet)
+
+       This event is used to request a PIN Code reply from user space.
+       The reply should either be returned using the PIN Code Reply or
+       the PIN Code Negative Reply command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
 
        Secure: 0x01  secure PIN code required
                0x00  secure PIN code not required
@@ -1011,44 +2765,81 @@ Event Parameters        Address (6 Octets)
 User Confirmation Request Event
 ===============================
 
-Event Code             0x000F
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       Confirm_Hint (1 Octet)
-                       Value (4 Octets)
+       Event Code:             0x000F
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Confirm_Hint (1 Octet)
+                               Value (4 Octets)
+
+       This event is used to request a user confirmation request from
+       user space.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       If the Confirm_Hint parameter value is 0x01 this means that
+       a simple "Yes/No" confirmation should be presented to the user
+       instead of a full numerical confirmation (in which case the
+       parameter value will be 0x00).
+
+       User space should respond to this command either using the User
+       Confirmation Reply or the User Confirmation Negative Reply
+       command.
 
 
 User Passkey Request Event
 ==========================
 
-Event Code             0x0010
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
+       Event Code:             0x0010
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This event is used to request a passkey from user space. The
+       response to this event should either be the User Passkey Reply
+       command or the User Passkey Negative Reply command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
 
 
 Authentication Failed Event
 ===========================
 
-Event Code             0x0011
-Controller Index:      <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       Status (1 Octet)
+       Event Code:             0x0011
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Status (1 Octet)
+
+       This event indicates that there was an authentication failure
+       with a remote device.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
 
 
 Device Found Event
 ==================
 
-Event Code             0x0012
-Controller Index       <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
-                       RSSI (1 Octet)
-                       Flags (4 Octets)
-                       EIR_Data_Length (2 Octets)
-                       EIR_Data (0-65535 Octets)
+       Event Code:             0x0012
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               RSSI (1 Octet)
+                               Flags (4 Octets)
+                               EIR_Data_Length (2 Octets)
+                               EIR_Data (0-65535 Octets)
+
+       This event indicates that a device was found during device
+       discovery.
 
        Possible values for the Address_Type parameter:
                0       BR/EDR
@@ -1058,39 +2849,376 @@ Event Parameters       Address (6 Octets)
        The following bits are defined for the Flags parameter:
                0       Confirm name
                1       Legacy Pairing
+               2       Not Connectable
+
+       For the RSSI field a value of 127 indicates that the RSSI is
+       not available. That can happen with Bluetooth 1.1 and earlier
+       controllers or with bad radio conditions.
+
+       The Confirm name flag indicates that the kernel wants to know
+       whether user space knows the name for this device or not. If
+       this flag is set user space should respond to it using the
+       Confirm Name command.
+
+       The Legacy Pairing flag indicates that Legacy Pairing is likely
+       to occur when pairing with this device. An application could use
+       this information to optimize the pairing process by locally
+       pre-generating a PIN code and thereby eliminate the risk of
+       local input timeout when pairing. Note that there is a risk of
+       false-positives for this flag so user space should be able to
+       handle getting something else as a PIN Request when pairing.
+
+       The Not Connectable flag indicates that the device will not
+       accept any connections. This can be indicated by Low Energy
+       devices that are in broadcaster role.
 
 
 Discovering Event
 =================
 
-Event Code             0x0013
-Controller Index       <controller id>
-Event Parameters       Address_Type (1 Octet)
-                       Discovering (1 Octet)
+       Event Code:             0x0013
+       Controller Index:       <controller id>
+       Event Parameters:       Address_Type (1 Octet)
+                               Discovering (1 Octet)
+
+       This event indicates that the controller has started discovering
+       devices. This discovering state can come and go multiple times
+       between a Start Discovery and a Stop Discovery commands.
+
+       The Start Service Discovery command will also trigger this event.
+
+       The valid values for the Discovering parameter are 0x01
+       (enabled) and 0x00 (disabled).
 
 
 Device Blocked Event
 ====================
 
-Event Code             0x0014
-Controller Index       <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
+       Event Code:             0x0014
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This event indicates that a device has been blocked using the
+       Block Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The event will only be sent to Management sockets other than the
+       one through which the command was sent.
 
 
 Device Unblocked Event
 ======================
 
-Event Code             0x0015
-Controller Index       <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
+       Event Code:             0x0015
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This event indicates that a device has been unblocked using the
+       Unblock Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The event will only be sent to Management sockets other than the
+       one through which the command was sent.
 
 
 Device Unpaired Event
 =====================
 
-Event Code             0x0016
-Controller Index       <controller id>
-Event Parameters       Address (6 Octets)
-                       Address_Type (1 Octet)
+       Event Code:             0x0016
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This event indicates that a device has been unpaired (i.e. all
+       its keys have been removed from the kernel) using the Unpair
+       Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       For devices using resolvable random addresses with a known
+       identity resolving key, the event paramters will contain
+       the identity. After receiving this event, the device will
+       become essentially private again.
+
+       The event will only be sent to Management sockets other than the
+       one through which the Unpair Device command was sent.
+
+
+Passkey Notify Event
+====================
+
+       Event Code:             0x0017
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Passkey (4 Octets)
+                               Entered (1 Octet)
+
+       This event is used to request passkey notification to the user.
+       Unlike the other authentication events it does not need
+       responding to using any Management command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The Passkey parameter indicates the passkey to be shown to the
+       user whereas the Entered parameter indicates how many characters
+       the user has entered on the remote side.
+
+
+New Identity Resolving Key Event
+================================
+
+       Event Code:             0x0018
+       Controller Index:       <controller id>
+       Event Parameters:       Store_Hint (1 Octet)
+                               Random_Address (6 Octets)
+                               Key {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Value (16 Octets)
+                               }
+
+       This event indicates that a new identity resolving key has been
+       generated for a remote device.
+
+       The Store_Hint parameter indicates whether the host is expected
+       to store the key persistently or not.
+
+       The Random_Address provides the resolvable random address that
+       was resolved into an identity. A value of 00:00:00:00:00:00
+       indicates that the identity resolving key was provided for
+       a public address or static random address.
+
+       Once this event has been send for a resolvable random address,
+       all further events mapping this device will send out using the
+       identity address information.
+
+       This event also indicates that now the identity address should
+       be used for commands instead of the resolvable random address.
+
+       It is possible that some devices allow discovering via its
+       identity address, but after pairing using resolvable private
+       address only. In such a case Store_Hint will be 0x00 and the
+       Random_Address will indicate 00:00:00:00:00:00. For these devices,
+       the Privacy Characteristic of the remote GATT database should
+       be consulted to decide if the identity resolving key must be
+       stored persistently or not.
+
+       Devices using Set Privacy command with the option 0x02 would
+       be such type of device.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
+
+
+New Signature Resolving Key Event
+=================================
+
+       Event Code:             0x0019
+       Controller Index:       <controller id>
+       Event Parameters:       Store_Hint (1 Octet)
+                               Key {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Type (1 Octet)
+                                       Value (16 Octets)
+                               }
+
+       This event indicates that a new signature resolving key has been
+       generated for either the master or slave device.
+
+       The Store_Hint parameter indicates whether the host is expected
+       to store the key persistently or not.
+
+       The Type parameter has the following possible values:
+
+               0x00    Unauthenticated local CSRK
+               0x01    Unauthenticated remote CSRK
+               0x02    Authenticated local CSRK
+               0x03    Authenticated remote CSRK
+
+       The local keys are used for signing data to be sent to the
+       remote device, whereas the remote keys are used to verify
+       signatures received from the remote device.
+
+       The local signature resolving key will be generated with each
+       pairing request. Only after receiving this event with the Type
+       indicating a local key is it possible to use ATT Signed Write
+       procedures.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The provided Address and Address_Type are the identity of
+       a device. So either its public address or static random address.
+
+
+Device Added Event
+==================
+
+       Event Code:             0x001a
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+                               Action (1 Octet)
+
+       This event indicates that a device has been added using the
+       Add Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The event will only be sent to management sockets other than the
+       one through which the command was sent.
+
+
+Device Removed Event
+====================
+
+       Event Code:             0x001b
+       Controller Index:       <controller id>
+       Event Parameters:       Address (6 Octets)
+                               Address_Type (1 Octet)
+
+       This event indicates that a device has been removed using the
+       Remove Device command.
+
+       Possible values for the Address_Type parameter:
+               0       BR/EDR
+               1       LE Public
+               2       LE Random
+
+       The event will only be sent to management sockets other than the
+       one through which the command was sent.
+
+
+New Connection Parameter Event
+==============================
+
+       Event Code:             0x001c
+       Controller Index:       <controller id>
+       Event Parameters:       Store_Hint (1 Octet)
+                               Param {
+                                       Address (6 Octets)
+                                       Address_Type (1 Octet)
+                                       Min_Connection_Interval (2 Octets)
+                                       Max_Connection_Interval (2 Octes)
+                                       Connection_Latency (2 Octets)
+                                       Supervision_Timeout (2 Octets)
+                               }
+
+       This event indicates a new set of connection parameters from
+       a peripheral device.
+
+       The Store_Hint parameter indicates whether the host is expected
+       to store this information persistently or not.
+
+       Possible values for the Address_Type parameter:
+               0       Reserved (not in use)
+               1       LE Public
+               2       LE Random
+
+       The Min_Connection_Interval, Max_Connection_Interval,
+       Connection_Latency and Supervision_Timeout parameters are
+       encoded as described in Core 4.1 spec, Vol 2, 7.7.65.3.
+
+
+Unconfigured Index Added Event
+==============================
+
+       Event Code:             0x001d
+       Controller Index:       <controller id>
+       Event Parameters:
+
+       This event indicates that a new unconfigured controller has been
+       added to the system. It is usually followed by a Read Controller
+       Configuration Information command.
+
+       Only when a controller requires further configuration, it will
+       be announced with this event. If it supports configuration, but
+       does not require it, then an Index Added event will be used.
+
+       Once the Read Extended Controller Index List command has been
+       used at least once, the Extended Index Added event will be
+       send instead of this one.
+
+
+Unconfigured Index Removed Event
+================================
+
+       Event Code:             0x001e
+       Controller Index:       <controller id>
+       Event Parameters:
+
+       This event indicates that an unconfigured controller has been
+       removed from the system.
+
+       Once the Read Extended Controller Index List command has been
+       used at least once, the Extended Index Removed event will be
+       send instead of this one.
+
+
+New Configuration Options Event
+===============================
+
+       Event Code:             0x001f
+       Controller Index:       <controller id>
+       Event Parameters:       Missing_Options (4 Octets)
+
+       This event indicates that one or more of the options for the
+       controller configuration has changed.
+
+
+Extended Index Added Event
+==========================
+
+       Event Code:             0x0020
+       Controller Index:       <controller id>
+       Event Parameters:       Controller_Type (1 Octet)
+
+       This event indicates that a new controller index has been
+       added to the system.
+
+       This event will only be used after Read Extended Controller Index
+       List has been used at least once. If it has not been used, then
+       Index Added and Unconfigured Index Added are send instead.
+
+
+Extended Index Removed Event
+============================
+
+       Event Code:             0x0021
+       Controller Index:       <controller id>
+       Event Parameters:       Controller_Type (1 Octet)
+
+       This event indicates that an existing controller index has been
+       removed from the system.
+
+       This event will only be used after Read Extended Controller Index
+       List has been used at least once. If it has not been used, then
+       Index Removed and Unconfigured Index Removed are send instead.