From dcbabfeb17c3c2fdb6bc92a3031ecd37df1834a8 Mon Sep 17 00:00:00 2001 From: Marek Szyprowski Date: Wed, 8 Jul 2020 15:38:00 +0200 Subject: [PATCH] phy: exynos5-usbdrd: Calibrating makes sense only for USB2.0 PHY PHY calibration is needed only for USB2.0 (UTMI) PHY, so skip calling calibration code when phy_calibrate() is called for USB3.0 (PIPE3) PHY. Fixes: d8c80bb3b55b ("phy: exynos5-usbdrd: Calibrate LOS levels for exynos5420/5800") Signed-off-by: Marek Szyprowski Acked-by: Krzysztof Kozlowski Link: https://lore.kernel.org/r/20200708133800.3336-1-m.szyprowski@samsung.com Signed-off-by: Vinod Koul --- drivers/phy/samsung/phy-exynos5-usbdrd.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/phy/samsung/phy-exynos5-usbdrd.c b/drivers/phy/samsung/phy-exynos5-usbdrd.c index eb06ce9..9930d20 100644 --- a/drivers/phy/samsung/phy-exynos5-usbdrd.c +++ b/drivers/phy/samsung/phy-exynos5-usbdrd.c @@ -714,7 +714,9 @@ static int exynos5_usbdrd_phy_calibrate(struct phy *phy) struct phy_usb_instance *inst = phy_get_drvdata(phy); struct exynos5_usbdrd_phy *phy_drd = to_usbdrd_phy(inst); - return exynos5420_usbdrd_phy_calibrate(phy_drd); + if (inst->phy_cfg->id == EXYNOS5_DRDPHY_UTMI) + return exynos5420_usbdrd_phy_calibrate(phy_drd); + return 0; } static const struct phy_ops exynos5_usbdrd_phy_ops = { -- 2.7.4