From cc54a660a6332a55cee487b009c332200580b45b Mon Sep 17 00:00:00 2001 From: Harinath Nampally Date: Sun, 5 Nov 2017 13:00:02 -0500 Subject: [PATCH] iio: accel: mma8452: Rename a struct for code readibility Rename time step look up struct to generic name as the values in the look table are same for all the other events like pulse, transient etc. Signed-off-by: Harinath Nampally Acked-by: Martin Kepplinger Signed-off-by: Jonathan Cameron --- drivers/iio/accel/mma8452.c | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/drivers/iio/accel/mma8452.c b/drivers/iio/accel/mma8452.c index bfd4bc8..16adf47 100644 --- a/drivers/iio/accel/mma8452.c +++ b/drivers/iio/accel/mma8452.c @@ -284,7 +284,7 @@ static const int mma8452_samp_freq[8][2] = { }; /* Datasheet table: step time "Relationship with the ODR" (sample frequency) */ -static const unsigned int mma8452_transient_time_step_us[4][8] = { +static const unsigned int mma8452_time_step_us[4][8] = { { 1250, 2500, 5000, 10000, 20000, 20000, 20000, 20000 }, /* normal */ { 1250, 2500, 5000, 10000, 20000, 80000, 80000, 80000 }, /* l p l n */ { 1250, 2500, 2500, 2500, 2500, 2500, 2500, 2500 }, /* high res*/ @@ -826,7 +826,7 @@ static int mma8452_read_event_value(struct iio_dev *indio_dev, if (power_mode < 0) return power_mode; - us = ret * mma8452_transient_time_step_us[power_mode][ + us = ret * mma8452_time_step_us[power_mode][ mma8452_get_odr_index(data)]; *val = us / USEC_PER_SEC; *val2 = us % USEC_PER_SEC; @@ -883,7 +883,7 @@ static int mma8452_write_event_value(struct iio_dev *indio_dev, return ret; steps = (val * USEC_PER_SEC + val2) / - mma8452_transient_time_step_us[ret][ + mma8452_time_step_us[ret][ mma8452_get_odr_index(data)]; if (steps < 0 || steps > 0xff) -- 2.7.4