From c22fca40522e2be8af168f3087d87d85e404ea72 Mon Sep 17 00:00:00 2001 From: Linus Walleij Date: Tue, 8 Mar 2022 16:44:25 +0100 Subject: [PATCH] power: ab8500_chargalg: Use CLOCK_MONOTONIC The HRTimer in the AB8500 charging code is using CLOCK_REALTIME to set an alarm some hours forward in time +/- 5 min for a safety timer. I have observed that this will sometimes fire sporadically early when charging a battery with the result that charging stops. As CLOCK_REALTIME can be subject to adjustments of time from sources such as NTP, this cannot be trusted and will likely for example fire events if the clock is set forward some hours by say NTP. Use CLOCK_MONOTONIC as indicated in other instances and the problem goes away. Also initialize the timer to REL mode as this is what will be used later. Fixes: 257107ae6b9b ("ab8500-chargalg: Use hrtimer") Cc: Lee Jones Suggested-by: Matti Vaittinen Signed-off-by: Linus Walleij Reviewed-by: Matti Vaittinen Signed-off-by: Sebastian Reichel --- drivers/power/supply/ab8500_chargalg.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/power/supply/ab8500_chargalg.c b/drivers/power/supply/ab8500_chargalg.c index cd7de11..431bbc3 100644 --- a/drivers/power/supply/ab8500_chargalg.c +++ b/drivers/power/supply/ab8500_chargalg.c @@ -1775,11 +1775,11 @@ static int ab8500_chargalg_probe(struct platform_device *pdev) psy_cfg.drv_data = di; /* Initilialize safety timer */ - hrtimer_init(&di->safety_timer, CLOCK_REALTIME, HRTIMER_MODE_ABS); + hrtimer_init(&di->safety_timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL); di->safety_timer.function = ab8500_chargalg_safety_timer_expired; /* Initilialize maintenance timer */ - hrtimer_init(&di->maintenance_timer, CLOCK_REALTIME, HRTIMER_MODE_ABS); + hrtimer_init(&di->maintenance_timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL); di->maintenance_timer.function = ab8500_chargalg_maintenance_timer_expired; -- 2.7.4