From b2173e49cab44dc1dbcecba3b659b5225a882114 Mon Sep 17 00:00:00 2001 From: Varadarajan Narayanan Date: Fri, 20 Oct 2023 11:49:33 +0530 Subject: [PATCH] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll [ Upstream commit 267e29198436a8cb6770213471f72502c895096a ] The set rate and determine rate operations are different between Stromer and Stromer Plus PLLs. Since the programming sequence is different, the PLLs dont get configured properly and random, inexplicable crash/freeze is seen. Hence, use stromer plus ops for ipq_pll_stromer_plus. Reviewed-by: Dmitry Baryshkov Acked-by: Stephen Boyd Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332") Signed-off-by: Kathiravan T Signed-off-by: Varadarajan Narayanan Link: https://lore.kernel.org/r/c86ecaa23dc4f39650bcf4a3bd54a617a932e4fd.1697781921.git.quic_varada@quicinc.com Signed-off-by: Bjorn Andersson Signed-off-by: Sasha Levin --- drivers/clk/qcom/apss-ipq-pll.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/clk/qcom/apss-ipq-pll.c b/drivers/clk/qcom/apss-ipq-pll.c index e170331..18c4ffe 100644 --- a/drivers/clk/qcom/apss-ipq-pll.c +++ b/drivers/clk/qcom/apss-ipq-pll.c @@ -68,7 +68,7 @@ static struct clk_alpha_pll ipq_pll_stromer_plus = { .fw_name = "xo", }, .num_parents = 1, - .ops = &clk_alpha_pll_stromer_ops, + .ops = &clk_alpha_pll_stromer_plus_ops, }, }, }; -- 2.7.4