From 793a3704589358ac55e7ec881552b250f384a6ec Mon Sep 17 00:00:00 2001 From: Evgeny Boger Date: Wed, 12 Jan 2022 11:47:27 +0300 Subject: [PATCH] power: supply: axp20x_battery: properly report current when discharging [ Upstream commit d4f408cdcd26921c1268cb8dcbe8ffb6faf837f3 ] As stated in [1], negative current values are used for discharging batteries. AXP PMICs internally have two different ADC channels for shunt current measurement: one used during charging and one during discharging. The values reported by these ADCs are unsigned. While the driver properly selects ADC channel to get the data from, it doesn't apply negative sign when reporting discharging current. [1] Documentation/ABI/testing/sysfs-class-power Signed-off-by: Evgeny Boger Acked-by: Chen-Yu Tsai Signed-off-by: Sebastian Reichel Signed-off-by: Sasha Levin --- drivers/power/supply/axp20x_battery.c | 13 ++++++------- 1 file changed, 6 insertions(+), 7 deletions(-) diff --git a/drivers/power/supply/axp20x_battery.c b/drivers/power/supply/axp20x_battery.c index 18a9db0..335e12c 100644 --- a/drivers/power/supply/axp20x_battery.c +++ b/drivers/power/supply/axp20x_battery.c @@ -186,7 +186,6 @@ static int axp20x_battery_get_prop(struct power_supply *psy, union power_supply_propval *val) { struct axp20x_batt_ps *axp20x_batt = power_supply_get_drvdata(psy); - struct iio_channel *chan; int ret = 0, reg, val1; switch (psp) { @@ -266,12 +265,12 @@ static int axp20x_battery_get_prop(struct power_supply *psy, if (ret) return ret; - if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) - chan = axp20x_batt->batt_chrg_i; - else - chan = axp20x_batt->batt_dischrg_i; - - ret = iio_read_channel_processed(chan, &val->intval); + if (reg & AXP20X_PWR_STATUS_BAT_CHARGING) { + ret = iio_read_channel_processed(axp20x_batt->batt_chrg_i, &val->intval); + } else { + ret = iio_read_channel_processed(axp20x_batt->batt_dischrg_i, &val1); + val->intval = -val1; + } if (ret) return ret; -- 2.7.4