From 63fc444967591c3849438aa0f21d5de96a928311 Mon Sep 17 00:00:00 2001 From: Daniel Baluta Date: Thu, 11 Jun 2015 18:49:33 +0300 Subject: [PATCH] iio: ABI: Clarify proximity output value Current description for proximity measurement is ambiguous. While the first part says that proximity is measured by observing reflectivity, the second part incorrectly infers that reported values should behave like a distance. This is because of AS3935 lightning sensor which uses the proximity API, while not being a true proximity sensor. Note this is marked for stable as it accompanies a fix in ABI usage to the sx9500 driver which would otherwise appear to be correct. Fixes: 614e8842ddf ("iio: ABI: add clarification for proximity") Signed-off-by: Daniel Baluta Cc: Signed-off-by: Jonathan Cameron --- Documentation/ABI/testing/sysfs-bus-iio | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-) diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index bbed111..70c9b1a 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -1234,10 +1234,8 @@ Description: object is near the sensor, usually be observing reflectivity of infrared or ultrasound emitted. Often these sensors are unit less and as such conversion - to SI units is not possible. Where it is, the units should - be meters. If such a conversion is not possible, the reported - values should behave in the same way as a distance, i.e. lower - values indicate something is closer to the sensor. + to SI units is not possible. Higher proximity measurements + indicate closer objects, and vice versa. What: /sys/.../iio:deviceX/in_illuminance_input What: /sys/.../iio:deviceX/in_illuminance_raw -- 2.7.4