From 37688852fd6f4fed2b3800a7652be87147137125 Mon Sep 17 00:00:00 2001 From: Krzysztof Kozlowski Date: Tue, 7 Feb 2023 20:28:50 +0100 Subject: [PATCH] ARM: dts: exynos: move MIPI phy to PMU node in Exynos3250 The MIPI phy is actually part of the Power Management Unit system controller. It does not have its own address space, thus keeping the node under soc causes warnings: exynos3250-artik5-eval.dtb: soc: video-phy: {'compatible': ['samsung,s5pv210-mipi-video-phy'], '#phy-cells': [[1]], 'syscon': [[15]], 'phandle': [[23]]} should not be valid under {'type': 'object'} Link: https://lore.kernel.org/r/20230207192851.549242-2-krzysztof.kozlowski@linaro.org Signed-off-by: Krzysztof Kozlowski --- arch/arm/boot/dts/exynos3250.dtsi | 11 +++++------ 1 file changed, 5 insertions(+), 6 deletions(-) diff --git a/arch/arm/boot/dts/exynos3250.dtsi b/arch/arm/boot/dts/exynos3250.dtsi index 28bb2ce..cb2c59c 100644 --- a/arch/arm/boot/dts/exynos3250.dtsi +++ b/arch/arm/boot/dts/exynos3250.dtsi @@ -346,7 +346,7 @@ }; pmu_system_controller: system-controller@10020000 { - compatible = "samsung,exynos3250-pmu", "syscon"; + compatible = "samsung,exynos3250-pmu", "simple-mfd", "syscon"; reg = <0x10020000 0x4000>; interrupt-controller; #interrupt-cells = <3>; @@ -354,12 +354,11 @@ clock-names = "clkout8"; clocks = <&cmu CLK_FIN_PLL>; #clock-cells = <1>; - }; - mipi_phy: video-phy { - compatible = "samsung,s5pv210-mipi-video-phy"; - #phy-cells = <1>; - syscon = <&pmu_system_controller>; + mipi_phy: mipi-phy { + compatible = "samsung,s5pv210-mipi-video-phy"; + #phy-cells = <1>; + }; }; pd_cam: power-domain@10023c00 { -- 2.7.4