From 2e28f7dd3743bf8f386fa72b96e5da2898039df5 Mon Sep 17 00:00:00 2001 From: Ansuel Smith Date: Tue, 7 Sep 2021 23:25:42 +0200 Subject: [PATCH] thermal/drivers/tsens: Fix wrong check for tzd in irq handlers [ Upstream commit cf96921876dcee4d6ac07b9de470368a075ba9ad ] Some devices can have some thermal sensors disabled from the factory. The current two irq handler functions check all the sensor by default and the check if the sensor was actually registered is wrong. The tzd is actually never set if the registration fails hence the IS_ERR check is wrong. Signed-off-by: Ansuel Smith Reviewed-by: Matthias Kaehlcke Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20210907212543.20220-1-ansuelsmth@gmail.com Signed-off-by: Sasha Levin --- drivers/thermal/qcom/tsens.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/thermal/qcom/tsens.c b/drivers/thermal/qcom/tsens.c index 3c4c051..cb4f4b5 100644 --- a/drivers/thermal/qcom/tsens.c +++ b/drivers/thermal/qcom/tsens.c @@ -415,7 +415,7 @@ static irqreturn_t tsens_critical_irq_thread(int irq, void *data) const struct tsens_sensor *s = &priv->sensor[i]; u32 hw_id = s->hw_id; - if (IS_ERR(s->tzd)) + if (!s->tzd) continue; if (!tsens_threshold_violated(priv, hw_id, &d)) continue; @@ -465,7 +465,7 @@ static irqreturn_t tsens_irq_thread(int irq, void *data) const struct tsens_sensor *s = &priv->sensor[i]; u32 hw_id = s->hw_id; - if (IS_ERR(s->tzd)) + if (!s->tzd) continue; if (!tsens_threshold_violated(priv, hw_id, &d)) continue; -- 2.7.4