From 2bd3ed0479c35f7c8dadecf72b725ca0c20ea015 Mon Sep 17 00:00:00 2001 From: Matt Carlson Date: Mon, 9 Jun 2008 15:39:55 -0700 Subject: [PATCH] tg3: Fix 5714S / 5715S / 5780S link failures The git commit ef167e27039eeaea6d3cdd5c547b082e89840bdd entitled "Fix supporting flowctrl code" introduced a bug that prevents 5714S, 5715S and 5780S devices from falling back to a forced link mode. The problem is that the added flow control check will always fail if flow control is set to autoneg and either RX or TX (or both) flow control is enabled. The driver defaults to setting flow control to autoneg and advertises both RX and TX flow control. The fix is to remove the errant check. Signed-off-by: Matt Carlson Signed-off-by: Michael Chan Signed-off-by: David S. Miller --- drivers/net/tg3.c | 3 +-- 1 file changed, 1 insertion(+), 2 deletions(-) diff --git a/drivers/net/tg3.c b/drivers/net/tg3.c index 07b3f77..4c248d7 100644 --- a/drivers/net/tg3.c +++ b/drivers/net/tg3.c @@ -3168,8 +3168,7 @@ static int tg3_setup_fiber_mii_phy(struct tg3 *tp, int force_reset) err |= tg3_readphy(tp, MII_BMCR, &bmcr); if ((tp->link_config.autoneg == AUTONEG_ENABLE) && !force_reset && - (tp->tg3_flags2 & TG3_FLG2_PARALLEL_DETECT) && - tp->link_config.flowctrl == tp->link_config.active_flowctrl) { + (tp->tg3_flags2 & TG3_FLG2_PARALLEL_DETECT)) { /* do nothing, just check for link up at the end */ } else if (tp->link_config.autoneg == AUTONEG_ENABLE) { u32 adv, new_adv; -- 2.7.4