From 06a09dc318e4ee91be630a99dc7cd6b92aa44d3d Mon Sep 17 00:00:00 2001 From: Miquel Raynal Date: Wed, 31 Jul 2019 14:21:20 +0200 Subject: [PATCH] dt-bindings: phy: Add Marvell COMPHY clocks Marvell CP110 COMPHY block is fed by 3 clocks. Describe each of them in the bindings. Signed-off-by: Miquel Raynal Reviewed-by: Rob Herring Signed-off-by: Kishon Vijay Abraham I --- Documentation/devicetree/bindings/phy/phy-mvebu-comphy.txt | 10 ++++++++++ 1 file changed, 10 insertions(+) diff --git a/Documentation/devicetree/bindings/phy/phy-mvebu-comphy.txt b/Documentation/devicetree/bindings/phy/phy-mvebu-comphy.txt index cf2cd86..8c60e69 100644 --- a/Documentation/devicetree/bindings/phy/phy-mvebu-comphy.txt +++ b/Documentation/devicetree/bindings/phy/phy-mvebu-comphy.txt @@ -25,6 +25,13 @@ Required properties: - #address-cells: should be 1. - #size-cells: should be 0. +Optional properlties: + +- clocks: pointers to the reference clocks for this device (CP110 only), + consequently: MG clock, MG Core clock, AXI clock. +- clock-names: names of used clocks for CP110 only, must be : + "mg_clk", "mg_core_clk" and "axi_clk". + A sub-node is required for each comphy lane provided by the comphy. Required properties (child nodes): @@ -39,6 +46,9 @@ Examples: compatible = "marvell,comphy-cp110"; reg = <0x120000 0x6000>; marvell,system-controller = <&cpm_syscon0>; + clocks = <&CP110_LABEL(clk) 1 5>, <&CP110_LABEL(clk) 1 6>, + <&CP110_LABEL(clk) 1 18>; + clock-names = "mg_clk", "mg_core_clk", "axi_clk"; #address-cells = <1>; #size-cells = <0>; -- 2.7.4