From: Hyeongsik Min Date: Mon, 8 May 2017 12:44:17 +0000 (+0900) Subject: Fix gdbus name and path X-Git-Tag: accepted/tizen/unified/20170602.054035~23 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=refs%2Fchanges%2F06%2F128306%2F1;p=platform%2Fcore%2Fsystem%2Fperipheral-bus.git Fix gdbus name and path This change fixes macro name along with the change in peripheal-io. Change-Id: Ifd6f03126e1dabd6488172268d557c8c1da93caa Signed-off-by: Hyeongsik Min --- diff --git a/src/daemon/peripheral_bus.c b/src/daemon/peripheral_bus.c index a73b876..bc943e0 100644 --- a/src/daemon/peripheral_bus.c +++ b/src/daemon/peripheral_bus.c @@ -20,8 +20,7 @@ #include #include -#include -#include +#include #include "peripheral_io_gdbus.h" #include "peripheral_bus.h" @@ -463,7 +462,7 @@ static gboolean __gpio_init(peripheral_bus_s *pb_data) G_CALLBACK(handle_gpio_unregister_irq), pb_data); - manager = g_dbus_object_manager_server_new(PERIPHERAL_DBUS_GPIO_PATH); + manager = g_dbus_object_manager_server_new(PERIPHERAL_GDBUS_GPIO_PATH); /* Set connection to 'manager' */ g_dbus_object_manager_server_set_connection(manager, pb_data->connection); @@ -471,7 +470,7 @@ static gboolean __gpio_init(peripheral_bus_s *pb_data) /* Export 'manager' interface on peripheral-io DBUS */ ret = g_dbus_interface_skeleton_export( G_DBUS_INTERFACE_SKELETON(pb_data->gpio_skeleton), - pb_data->connection, PERIPHERAL_DBUS_GPIO_PATH, &error); + pb_data->connection, PERIPHERAL_GDBUS_GPIO_PATH, &error); if (ret == FALSE) { _E("Can not skeleton_export %s", error->message); @@ -506,7 +505,7 @@ static gboolean __i2c_init(peripheral_bus_s *pb_data) G_CALLBACK(handle_i2c_write), pb_data); - manager = g_dbus_object_manager_server_new(PERIPHERAL_DBUS_I2C_PATH); + manager = g_dbus_object_manager_server_new(PERIPHERAL_GDBUS_I2C_PATH); /* Set connection to 'manager' */ g_dbus_object_manager_server_set_connection(manager, pb_data->connection); @@ -514,7 +513,7 @@ static gboolean __i2c_init(peripheral_bus_s *pb_data) /* Export 'manager' interface on peripheral-io DBUS */ ret = g_dbus_interface_skeleton_export( G_DBUS_INTERFACE_SKELETON(pb_data->i2c_skeleton), - pb_data->connection, PERIPHERAL_DBUS_I2C_PATH, &error); + pb_data->connection, PERIPHERAL_GDBUS_I2C_PATH, &error); if (ret == FALSE) { _E("Can not skeleton_export %s", error->message); @@ -561,7 +560,7 @@ static gboolean __pwm_init(peripheral_bus_s *pb_data) G_CALLBACK(handle_pwm_get_period), NULL); - manager = g_dbus_object_manager_server_new(PERIPHERAL_DBUS_PWM_PATH); + manager = g_dbus_object_manager_server_new(PERIPHERAL_GDBUS_PWM_PATH); /* Set connection to 'manager' */ g_dbus_object_manager_server_set_connection(manager, pb_data->connection); @@ -569,7 +568,7 @@ static gboolean __pwm_init(peripheral_bus_s *pb_data) /* Export 'manager' interface on peripheral-io DBUS */ ret = g_dbus_interface_skeleton_export( G_DBUS_INTERFACE_SKELETON(pb_data->pwm_skeleton), - pb_data->connection, PERIPHERAL_DBUS_PWM_PATH, &error); + pb_data->connection, PERIPHERAL_GDBUS_PWM_PATH, &error); if (ret == FALSE) { _E("Can not skeleton_export %s", error->message); @@ -620,7 +619,7 @@ int main(int argc, char *argv[]) } owner_id = g_bus_own_name(G_BUS_TYPE_SYSTEM, - PERIPHERAL_DBUS_NAME, + PERIPHERAL_GDBUS_NAME, (GBusNameOwnerFlags) (G_BUS_NAME_OWNER_FLAGS_ALLOW_REPLACEMENT | G_BUS_NAME_OWNER_FLAGS_REPLACE), on_bus_acquired,