From: Alexander Graf Date: Thu, 14 Jul 2011 09:52:08 +0000 (+0200) Subject: s390x: implement SIGP restart and shutdown X-Git-Tag: TizenStudio_2.0_p2.3~1940^2~5^2~7 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=ea760f4e4b2e222417113bc86041e3c4e2461e4e;p=sdk%2Femulator%2Fqemu.git s390x: implement SIGP restart and shutdown An s390x OS does reboot and shutdown triggers through hypercalls that we didn't implement on the TCG backend yet. That means that so far we couldn't shut down virtual machines for example, having them hang on shutdown when not using KVM. With this patch, this restriction is gone. We can now shut down and reboot s390x virtual machines even when using the TCG backend. Signed-off-by: Alexander Graf --- diff --git a/target-s390x/op_helper.c b/target-s390x/op_helper.c index 364b100..137bae7 100644 --- a/target-s390x/op_helper.c +++ b/target-s390x/op_helper.c @@ -29,6 +29,10 @@ #include #endif +#if !defined (CONFIG_USER_ONLY) +#include "sysemu.h" +#endif + /*****************************************************************************/ /* Softmmu support */ #if !defined (CONFIG_USER_ONLY) @@ -2901,6 +2905,16 @@ uint32_t HELPER(sigp)(uint64_t order_code, uint32_t r1, uint64_t cpu_addr) env->regs[r1] &= 0xffffffff00000000ULL; cc = 1; break; +#if !defined (CONFIG_USER_ONLY) + case SIGP_RESTART: + qemu_system_reset_request(); + cpu_loop_exit(env); + break; + case SIGP_STOP: + qemu_system_shutdown_request(); + cpu_loop_exit(env); + break; +#endif default: /* unknown sigp */ fprintf(stderr, "XXX unknown sigp: 0x%" PRIx64 "\n", order_code);