From: Thomas Richter Date: Mon, 26 Mar 2018 08:25:37 +0000 (+0200) Subject: perf vendor events s390: Add JSON files for IBM z13 X-Git-Tag: v4.19~1357^2~4^2~1 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=bc17f949d6feb633e579ee7e7dd58d9200073215;p=platform%2Fkernel%2Flinux-rpi.git perf vendor events s390: Add JSON files for IBM z13 Add CPU measurement counter facility event description files (json files) for IBM z13. Signed-off-by: Thomas Richter Reviewed-by: Hendrik Brueckner Cc: Heiko Carstens Cc: Martin Schwidefsky Link: http://lkml.kernel.org/r/20180326082538.2258-4-tmricht@linux.vnet.ibm.com Signed-off-by: Arnaldo Carvalho de Melo --- diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/basic.json b/tools/perf/pmu-events/arch/s390/cf_z13/basic.json new file mode 100644 index 0000000..8bf16759 --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z13/basic.json @@ -0,0 +1,74 @@ +[ + { + "EventCode": "0", + "EventName": "CPU_CYCLES", + "BriefDescription": "CPU Cycles", + "PublicDescription": "Cycle Count" + }, + { + "EventCode": "1", + "EventName": "INSTRUCTIONS", + "BriefDescription": "Instructions", + "PublicDescription": "Instruction Count" + }, + { + "EventCode": "2", + "EventName": "L1I_DIR_WRITES", + "BriefDescription": "L1I Directory Writes", + "PublicDescription": "Level-1 I-Cache Directory Write Count" + }, + { + "EventCode": "3", + "EventName": "L1I_PENALTY_CYCLES", + "BriefDescription": "L1I Penalty Cycles", + "PublicDescription": "Level-1 I-Cache Penalty Cycle Count" + }, + { + "EventCode": "4", + "EventName": "L1D_DIR_WRITES", + "BriefDescription": "L1D Directory Writes", + "PublicDescription": "Level-1 D-Cache Directory Write Count" + }, + { + "EventCode": "5", + "EventName": "L1D_PENALTY_CYCLES", + "BriefDescription": "L1D Penalty Cycles", + "PublicDescription": "Level-1 D-Cache Penalty Cycle Count" + }, + { + "EventCode": "32", + "EventName": "PROBLEM_STATE_CPU_CYCLES", + "BriefDescription": "Problem-State CPU Cycles", + "PublicDescription": "Problem-State Cycle Count" + }, + { + "EventCode": "33", + "EventName": "PROBLEM_STATE_INSTRUCTIONS", + "BriefDescription": "Problem-State Instructions", + "PublicDescription": "Problem-State Instruction Count" + }, + { + "EventCode": "34", + "EventName": "PROBLEM_STATE_L1I_DIR_WRITES", + "BriefDescription": "Problem-State L1I Directory Writes", + "PublicDescription": "Problem-State Level-1 I-Cache Directory Write Count" + }, + { + "EventCode": "35", + "EventName": "PROBLEM_STATE_L1I_PENALTY_CYCLES", + "BriefDescription": "Problem-State L1I Penalty Cycles", + "PublicDescription": "Problem-State Level-1 I-Cache Penalty Cycle Count" + }, + { + "EventCode": "36", + "EventName": "PROBLEM_STATE_L1D_DIR_WRITES", + "BriefDescription": "Problem-State L1D Directory Writes", + "PublicDescription": "Problem-State Level-1 D-Cache Directory Write Count" + }, + { + "EventCode": "37", + "EventName": "PROBLEM_STATE_L1D_PENALTY_CYCLES", + "BriefDescription": "Problem-State L1D Penalty Cycles", + "PublicDescription": "Problem-State Level-1 D-Cache Penalty Cycle Count" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json b/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json new file mode 100644 index 0000000..7e5b724 --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z13/crypto.json @@ -0,0 +1,98 @@ +[ + { + "EventCode": "64", + "EventName": "PRNG_FUNCTIONS", + "BriefDescription": "PRNG Functions", + "PublicDescription": "Total number of the PRNG functions issued by the CPU" + }, + { + "EventCode": "65", + "EventName": "PRNG_CYCLES", + "BriefDescription": "PRNG Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing PRNG functions issued by the CPU" + }, + { + "EventCode": "66", + "EventName": "PRNG_BLOCKED_FUNCTIONS", + "BriefDescription": "PRNG Blocked Functions", + "PublicDescription": "Total number of the PRNG functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "67", + "EventName": "PRNG_BLOCKED_CYCLES", + "BriefDescription": "PRNG Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the PRNG functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "68", + "EventName": "SHA_FUNCTIONS", + "BriefDescription": "SHA Functions", + "PublicDescription": "Total number of SHA functions issued by the CPU" + }, + { + "EventCode": "69", + "EventName": "SHA_CYCLES", + "BriefDescription": "SHA Cycles", + "PublicDescription": "Total number of CPU cycles when the SHA coprocessor is busy performing the SHA functions issued by the CPU" + }, + { + "EventCode": "70", + "EventName": "SHA_BLOCKED_FUNCTIONS", + "BriefDescription": "SHA Blocked Functions", + "PublicDescription": "Total number of the SHA functions that are issued by the CPU and are blocked because the SHA coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "71", + "EventName": "SHA_BLOCKED_CYCLES", + "BriefDescription": "SHA Bloced Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the SHA functions issued by the CPU because the SHA coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "72", + "EventName": "DEA_FUNCTIONS", + "BriefDescription": "DEA Functions", + "PublicDescription": "Total number of the DEA functions issued by the CPU" + }, + { + "EventCode": "73", + "EventName": "DEA_CYCLES", + "BriefDescription": "DEA Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the DEA functions issued by the CPU" + }, + { + "EventCode": "74", + "EventName": "DEA_BLOCKED_FUNCTIONS", + "BriefDescription": "DEA Blocked Functions", + "PublicDescription": "Total number of the DEA functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "75", + "EventName": "DEA_BLOCKED_CYCLES", + "BriefDescription": "DEA Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the DEA functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "76", + "EventName": "AES_FUNCTIONS", + "BriefDescription": "AES Functions", + "PublicDescription": "Total number of AES functions issued by the CPU" + }, + { + "EventCode": "77", + "EventName": "AES_CYCLES", + "BriefDescription": "AES Cycles", + "PublicDescription": "Total number of CPU cycles when the DEA/AES coprocessor is busy performing the AES functions issued by the CPU" + }, + { + "EventCode": "78", + "EventName": "AES_BLOCKED_FUNCTIONS", + "BriefDescription": "AES Blocked Functions", + "PublicDescription": "Total number of AES functions that are issued by the CPU and are blocked because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, + { + "EventCode": "79", + "EventName": "AES_BLOCKED_CYCLES", + "BriefDescription": "AES Blocked Cycles", + "PublicDescription": "Total number of CPU cycles blocked for the AES functions issued by the CPU because the DEA/AES coprocessor is busy performing a function issued by another CPU" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/cf_z13/extended.json b/tools/perf/pmu-events/arch/s390/cf_z13/extended.json new file mode 100644 index 0000000..9a002b6 --- /dev/null +++ b/tools/perf/pmu-events/arch/s390/cf_z13/extended.json @@ -0,0 +1,338 @@ +[ + { + "EventCode": "128", + "EventName": "L1D_RO_EXCL_WRITES", + "BriefDescription": "L1D Read-only Exclusive Writes", + "PublicDescription": "A directory write to the Level-1 Data cache where the line was originally in a Read-Only state in the cache but has been updated to be in the Exclusive state that allows stores to the cache line." + }, + { + "EventCode": "129", + "EventName": "DTLB1_WRITES", + "BriefDescription": "DTLB1 Writes", + "PublicDescription": "A translation entry has been written to the Level-1 Data Translation Lookaside Buffer" + }, + { + "EventCode": "130", + "EventName": "DTLB1_MISSES", + "BriefDescription": "DTLB1 Misses", + "PublicDescription": "Level-1 Data TLB miss in progress. Incremented by one for every cycle a DTLB1 miss is in progress." + }, + { + "EventCode": "131", + "EventName": "DTLB1_HPAGE_WRITES", + "BriefDescription": "DTLB1 One-Megabyte Page Writes", + "PublicDescription": "A translation entry has been written to the Level-1 Data Translation Lookaside Buffer for a one-megabyte page" + }, + { + "EventCode": "132", + "EventName": "DTLB1_GPAGE_WRITES", + "BriefDescription": "DTLB1 Two-Gigabyte Page Writes", + "PublicDescription": "Counter:132 Name:DTLB1_GPAGE_WRITES A translation entry has been written to the Level-1 Data Translation Lookaside Buffer for a two-gigabyte page." + }, + { + "EventCode": "133", + "EventName": "L1D_L2D_SOURCED_WRITES", + "BriefDescription": "L1D L2D Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the Level-2 Data cache" + }, + { + "EventCode": "134", + "EventName": "ITLB1_WRITES", + "BriefDescription": "ITLB1 Writes", + "PublicDescription": "A translation entry has been written to the Level-1 Instruction Translation Lookaside Buffer" + }, + { + "EventCode": "135", + "EventName": "ITLB1_MISSES", + "BriefDescription": "ITLB1 Misses", + "PublicDescription": "Level-1 Instruction TLB miss in progress. Incremented by one for every cycle an ITLB1 miss is in progress" + }, + { + "EventCode": "136", + "EventName": "L1I_L2I_SOURCED_WRITES", + "BriefDescription": "L1I L2I Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the Level-2 Instruction cache" + }, + { + "EventCode": "137", + "EventName": "TLB2_PTE_WRITES", + "BriefDescription": "TLB2 PTE Writes", + "PublicDescription": "A translation entry has been written to the Level-2 TLB Page Table Entry arrays" + }, + { + "EventCode": "138", + "EventName": "TLB2_CRSTE_HPAGE_WRITES", + "BriefDescription": "TLB2 CRSTE One-Megabyte Page Writes", + "PublicDescription": "A translation entry has been written to the Level-2 TLB Combined Region Segment Table Entry arrays for a one-megabyte large page translation" + }, + { + "EventCode": "139", + "EventName": "TLB2_CRSTE_WRITES", + "BriefDescription": "TLB2 CRSTE Writes", + "PublicDescription": "A translation entry has been written to the Level-2 TLB Combined Region Segment Table Entry arrays" + }, + { + "EventCode": "140", + "EventName": "TX_C_TEND", + "BriefDescription": "Completed TEND instructions in constrained TX mode", + "PublicDescription": "A TEND instruction has completed in a constrained transactional-execution mode" + }, + { + "EventCode": "141", + "EventName": "TX_NC_TEND", + "BriefDescription": "Completed TEND instructions in non-constrained TX mode", + "PublicDescription": "A TEND instruction has completed in a non-constrained transactional-execution mode" + }, + { + "EventCode": "143", + "EventName": "L1C_TLB1_MISSES", + "BriefDescription": "L1C TLB1 Misses", + "PublicDescription": "Increments by one for any cycle where a Level-1 cache or Level-1 TLB miss is in progress." + }, + { + "EventCode": "144", + "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES", + "BriefDescription": "L1D On-Chip L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache without intervention" + }, + { + "EventCode": "145", + "EventName": "L1D_ONCHIP_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D On-Chip L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-3 cache with intervention" + }, + { + "EventCode": "146", + "EventName": "L1D_ONNODE_L4_SOURCED_WRITES", + "BriefDescription": "L1D On-Node L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-4 cache" + }, + { + "EventCode": "147", + "EventName": "L1D_ONNODE_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D On-Node L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-3 cache with intervention" + }, + { + "EventCode": "148", + "EventName": "L1D_ONNODE_L3_SOURCED_WRITES", + "BriefDescription": "L1D On-Node L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Node Level-3 cache without intervention" + }, + { + "EventCode": "149", + "EventName": "L1D_ONDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1D On-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-4 cache" + }, + { + "EventCode": "150", + "EventName": "L1D_ONDRAWER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D On-Drawer L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache with intervention" + }, + { + "EventCode": "151", + "EventName": "L1D_ONDRAWER_L3_SOURCED_WRITES", + "BriefDescription": "L1D On-Drawer L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache without intervention" + }, + { + "EventCode": "152", + "EventName": "L1D_OFFDRAWER_SCOL_L4_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Same-Column L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-4 cache" + }, + { + "EventCode": "153", + "EventName": "L1D_OFFDRAWER_SCOL_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D Off-Drawer Same-Column L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache with intervention" + }, + { + "EventCode": "154", + "EventName": "L1D_OFFDRAWER_SCOL_L3_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Same-Column L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache without intervention" + }, + { + "EventCode": "155", + "EventName": "L1D_OFFDRAWER_FCOL_L4_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-4 cache" + }, + { + "EventCode": "156", + "EventName": "L1D_OFFDRAWER_FCOL_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache with intervention" + }, + { + "EventCode": "157", + "EventName": "L1D_OFFDRAWER_FCOL_L3_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Far-Column L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache without intervention" + }, + { + "EventCode": "158", + "EventName": "L1D_ONNODE_MEM_SOURCED_WRITES", + "BriefDescription": "L1D On-Node Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Node memory" + }, + { + "EventCode": "159", + "EventName": "L1D_ONDRAWER_MEM_SOURCED_WRITES", + "BriefDescription": "L1D On-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Drawer memory" + }, + { + "EventCode": "160", + "EventName": "L1D_OFFDRAWER_MEM_SOURCED_WRITES", + "BriefDescription": "L1D Off-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Drawer memory" + }, + { + "EventCode": "161", + "EventName": "L1D_ONCHIP_MEM_SOURCED_WRITES", + "BriefDescription": "L1D On-Chip Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from On-Chip memory" + }, + { + "EventCode": "162", + "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES", + "BriefDescription": "L1I On-Chip L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-3 cache without intervention" + }, + { + "EventCode": "163", + "EventName": "L1I_ONCHIP_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I On-Chip L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On Chip Level-3 cache with intervention" + }, + { + "EventCode": "164", + "EventName": "L1I_ONNODE_L4_SOURCED_WRITES", + "BriefDescription": "L1I On-Chip L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-4 cache" + }, + { + "EventCode": "165", + "EventName": "L1I_ONNODE_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I On-Node L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-3 cache with intervention" + }, + { + "EventCode": "166", + "EventName": "L1I_ONNODE_L3_SOURCED_WRITES", + "BriefDescription": "L1I On-Node L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Node Level-3 cache without intervention" + }, + { + "EventCode": "167", + "EventName": "L1I_ONDRAWER_L4_SOURCED_WRITES", + "BriefDescription": "L1I On-Drawer L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-4 cache" + }, + { + "EventCode": "168", + "EventName": "L1I_ONDRAWER_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I On-Drawer L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache with intervention" + }, + { + "EventCode": "169", + "EventName": "L1I_ONDRAWER_L3_SOURCED_WRITES", + "BriefDescription": "L1I On-Drawer L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-3 cache without intervention" + }, + { + "EventCode": "170", + "EventName": "L1I_OFFDRAWER_SCOL_L4_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Same-Column L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-4 cache" + }, + { + "EventCode": "171", + "EventName": "L1I_OFFDRAWER_SCOL_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I Off-Drawer Same-Column L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache with intervention" + }, + { + "EventCode": "172", + "EventName": "L1I_OFFDRAWER_SCOL_L3_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Same-Column L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Same-Column Level-3 cache without intervention" + }, + { + "EventCode": "173", + "EventName": "L1I_OFFDRAWER_FCOL_L4_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Far-Column L4 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-4 cache" + }, + { + "EventCode": "174", + "EventName": "L1I_OFFDRAWER_FCOL_L3_SOURCED_WRITES_IV", + "BriefDescription": "L1I Off-Drawer Far-Column L3 Sourced Writes with Intervention", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache with intervention" + }, + { + "EventCode": "175", + "EventName": "L1I_OFFDRAWER_FCOL_L3_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Far-Column L3 Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Far-Column Level-3 cache without intervention" + }, + { + "EventCode": "176", + "EventName": "L1I_ONNODE_MEM_SOURCED_WRITES", + "BriefDescription": "L1I On-Node Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Node memory" + }, + { + "EventCode": "177", + "EventName": "L1I_ONDRAWER_MEM_SOURCED_WRITES", + "BriefDescription": "L1I On-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Drawer memory" + }, + { + "EventCode": "178", + "EventName": "L1I_OFFDRAWER_MEM_SOURCED_WRITES", + "BriefDescription": "L1I Off-Drawer Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Drawer memory" + }, + { + "EventCode": "179", + "EventName": "L1I_ONCHIP_MEM_SOURCED_WRITES", + "BriefDescription": "L1I On-Chip Memory Sourced Writes", + "PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from On-Chip memory" + }, + { + "EventCode": "218", + "EventName": "TX_NC_TABORT", + "BriefDescription": "Aborted transactions in non-constrained TX mode", + "PublicDescription": "A transaction abort has occurred in a non-constrained transactional-execution mode" + }, + { + "EventCode": "219", + "EventName": "TX_C_TABORT_NO_SPECIAL", + "BriefDescription": "Aborted transactions in constrained TX mode not using special completion logic", + "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is not using any special logic to allow the transaction to complete" + }, + { + "EventCode": "220", + "EventName": "TX_C_TABORT_SPECIAL", + "BriefDescription": "Aborted transactions in constrained TX mode using special completion logic", + "PublicDescription": "A transaction abort has occurred in a constrained transactional-execution mode and the CPU is using special logic to allow the transaction to complete" + }, + { + "EventCode": "448", + "EventName": "MT_DIAG_CYCLES_ONE_THR_ACTIVE", + "BriefDescription": "Cycle count with one thread active", + "PublicDescription": "Cycle count with one thread active" + }, + { + "EventCode": "449", + "EventName": "MT_DIAG_CYCLES_TWO_THR_ACTIVE", + "BriefDescription": "Cycle count with two threads active", + "PublicDescription": "Cycle count with two threads active" + }, +] diff --git a/tools/perf/pmu-events/arch/s390/mapfile.csv b/tools/perf/pmu-events/arch/s390/mapfile.csv index c57f8e7..3cff9c64 100644 --- a/tools/perf/pmu-events/arch/s390/mapfile.csv +++ b/tools/perf/pmu-events/arch/s390/mapfile.csv @@ -2,3 +2,4 @@ Family-model,Version,Filename,EventType 209[78],1,cf_z10,core 281[78],1,cf_z196,core 282[78],1,cf_zec12,core +296[45],1,cf_z13,core