From: Geert Uytterhoeven Date: Fri, 18 Dec 2020 12:52:53 +0000 (+0100) Subject: clk: vc5: Use "idt,voltage-microvolt" instead of "idt,voltage-microvolts" X-Git-Tag: v5.15~2097^2^3 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=4b003f5fcadfa2d0e087e907b0c65d023f6e29fb;p=platform%2Fkernel%2Flinux-starfive.git clk: vc5: Use "idt,voltage-microvolt" instead of "idt,voltage-microvolts" Commit 45c940184b501fc6 ("dt-bindings: clk: versaclock5: convert to yaml") accidentally changed "idt,voltage-microvolts" to "idt,voltage-microvolt" in the DT bindings, while the driver still used the former. Update the driver to match the bindings, as Documentation/devicetree/bindings/property-units.txt actually recommends using "microvolt". Fixes: 260249f929e81d3d ("clk: vc5: Enable addition output configurations of the Versaclock") Signed-off-by: Geert Uytterhoeven Link: https://lore.kernel.org/r/20201218125253.3815567-1-geert+renesas@glider.be Reviewed-by: Luca Ceresoli Signed-off-by: Stephen Boyd --- diff --git a/drivers/clk/clk-versaclock5.c b/drivers/clk/clk-versaclock5.c index c90460e7ef21..43db67337bc0 100644 --- a/drivers/clk/clk-versaclock5.c +++ b/drivers/clk/clk-versaclock5.c @@ -739,8 +739,8 @@ static int vc5_update_power(struct device_node *np_output, { u32 value; - if (!of_property_read_u32(np_output, - "idt,voltage-microvolts", &value)) { + if (!of_property_read_u32(np_output, "idt,voltage-microvolt", + &value)) { clk_out->clk_output_cfg0_mask |= VC5_CLK_OUTPUT_CFG0_PWR_MASK; switch (value) { case 1800000: