From: Henrique de Moraes Holschuh Date: Thu, 19 Jul 2007 02:45:46 +0000 (-0300) Subject: ACPI: thinkpad-acpi: make EC-based thermal readings non-experimental X-Git-Tag: v3.12-rc1~27611^2~5^2~2 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=3d6f99ca00ccf861305fd8630a21f2e696886708;p=kernel%2Fkernel-generic.git ACPI: thinkpad-acpi: make EC-based thermal readings non-experimental Reading the 16 thermal sensors directly from the EC has been stable for about one year, in all supported ThinkPad models. Remove its "experimental" label. Signed-off-by: Henrique de Moraes Holschuh Signed-off-by: Len Brown --- diff --git a/Documentation/thinkpad-acpi.txt b/Documentation/thinkpad-acpi.txt index 5d827de..3eb949e 100644 --- a/Documentation/thinkpad-acpi.txt +++ b/Documentation/thinkpad-acpi.txt @@ -710,23 +710,15 @@ Temperature sensors procfs: /proc/acpi/ibm/thermal sysfs device attributes: (hwmon) temp*_input -Most ThinkPads include six or more separate temperature sensors but -only expose the CPU temperature through the standard ACPI methods. -This feature shows readings from up to eight different sensors on older -ThinkPads, and it has experimental support for up to sixteen different -sensors on newer ThinkPads. - -EXPERIMENTAL: The 16-sensors feature is marked EXPERIMENTAL because the -implementation directly accesses hardware registers and may not work as -expected. USE WITH CAUTION! To use this feature, you need to supply the -experimental=1 parameter when loading the module. When EXPERIMENTAL -mode is enabled, reading the first 8 sensors on newer ThinkPads will -also use an new experimental thermal sensor access mode. +Most ThinkPads include six or more separate temperature sensors but only +expose the CPU temperature through the standard ACPI methods. This +feature shows readings from up to eight different sensors on older +ThinkPads, and up to sixteen different sensors on newer ThinkPads. For example, on the X40, a typical output may be: temperatures: 42 42 45 41 36 -128 33 -128 -EXPERIMENTAL: On the T43/p, a typical output may be: +On the T43/p, a typical output may be: temperatures: 48 48 36 52 38 -128 31 -128 48 52 48 -128 -128 -128 -128 -128 The mapping of thermal sensors to physical locations varies depending on diff --git a/drivers/misc/thinkpad_acpi.c b/drivers/misc/thinkpad_acpi.c index f74d7d6..84a1000 100644 --- a/drivers/misc/thinkpad_acpi.c +++ b/drivers/misc/thinkpad_acpi.c @@ -2709,7 +2709,7 @@ static int __init thermal_init(struct ibm_init_struct *iibm) acpi_tmp7 = acpi_evalf(ec_handle, NULL, "TMP7", "qv"); - if (thinkpad_id.ec_model && experimental) { + if (thinkpad_id.ec_model) { /* * Direct EC access mode: sensors at registers * 0x78-0x7F, 0xC0-0xC7. Registers return 0x00 for