From: Heiko Stuebner Date: Fri, 9 May 2014 22:36:57 +0000 (-0700) Subject: drivers/rtc/rtc-hym8563.c: set uie_unsupported X-Git-Tag: v3.15-rc6~44^2~3 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=282cba6b00a95f0277ed71551e3f6b0477e8836b;p=platform%2Fkernel%2Flinux-stable.git drivers/rtc/rtc-hym8563.c: set uie_unsupported The alarm of the hym8563 only supports a minute accuracy, while the uie wants an alarm one second in the future. Therefore things like the select() syscall will fail with a timeout, because the next alarm will happen in a worst case of 60 seconds. Signed-off-by: Heiko Stuebner Cc: Alessandro Zummo Cc: Signed-off-by: Andrew Morton Signed-off-by: Linus Torvalds --- diff --git a/drivers/rtc/rtc-hym8563.c b/drivers/rtc/rtc-hym8563.c index bd628a6..e5f13c4 100644 --- a/drivers/rtc/rtc-hym8563.c +++ b/drivers/rtc/rtc-hym8563.c @@ -569,6 +569,9 @@ static int hym8563_probe(struct i2c_client *client, if (IS_ERR(hym8563->rtc)) return PTR_ERR(hym8563->rtc); + /* the hym8563 alarm only supports a minute accuracy */ + hym8563->rtc->uie_unsupported = 1; + #ifdef CONFIG_COMMON_CLK hym8563_clkout_register_clk(hym8563); #endif