From: Matthias Kaehlcke Date: Tue, 31 Jul 2018 18:59:17 +0000 (-0700) Subject: arm64: dts: qcom: pm8998: Add pm8998 thermal zone X-Git-Tag: v5.15~7693^2~20^2~4 X-Git-Url: http://review.tizen.org/git/?a=commitdiff_plain;h=1b9d8bd69305d9020534e09f3f790e43d1393b03;p=platform%2Fkernel%2Flinux-starfive.git arm64: dts: qcom: pm8998: Add pm8998 thermal zone The thermal zone uses spmi-temp-alarm as sensor, the trip points correspond to the PMIC thermal stages 1 and 2. The critical trip point at 125°C disables the partial PMIC shutdown at stage 2. Without an IIO input the sensor only reports a limited number of temperatures: - 37°C for temperatures below 105°C - 107°C for temperatures >= 105°C and < 125°C - 127°C for temperatures >= 125°C (the numbers correspond to a stage 1 threshold of 105°C) Signed-off-by: Matthias Kaehlcke Reviewed-by: Douglas Anderson Signed-off-by: Andy Gross --- diff --git a/arch/arm64/boot/dts/qcom/pm8998.dtsi b/arch/arm64/boot/dts/qcom/pm8998.dtsi index 8f20e33..048f19f 100644 --- a/arch/arm64/boot/dts/qcom/pm8998.dtsi +++ b/arch/arm64/boot/dts/qcom/pm8998.dtsi @@ -5,7 +5,31 @@ #include #include #include +#include +/ { + thermal-zones { + pm8998 { + polling-delay-passive = <250>; + polling-delay = <1000>; + + thermal-sensors = <&pm8998_temp>; + + trips { + pm8998_alert0: pm8998-alert0 { + temperature = <105000>; + hysteresis = <2000>; + type = "passive"; + }; + pm8998_crit: pm8998-crit { + temperature = <125000>; + hysteresis = <2000>; + type = "critical"; + }; + }; + }; + }; +}; &spmi_bus { pm8998_lsid0: pmic@0 {