DECON command mode can use hardware trigger where transmission
is triggered automatically, or software trigger - where TE interrupt
handler should trigger transmission.
DECON will use software trigger if TE interrupt is specified.
Signed-off-by: Andrzej Hajda <a.hajda@samsung.com>
Signed-off-by: Inki Dae <inki.dae@samsung.com>
- reg: physical base address and length of the DECON registers set.
- interrupt-names: should contain the interrupt names depending on mode of work:
video mode: "vsync",
- command mode: "lcd_sys".
+ command mode: "lcd_sys",
+ command mode with software trigger: "lcd_sys", "te".
- interrupts or interrupts-extended: list of interrupt specifiers corresponding
to names privided in interrupt-names, as described in
interrupt-controller/interrupts.txt