Update doxygen 84/214784/1
authormk5004.lee <mk5004.lee@samsung.com>
Thu, 26 Sep 2019 08:23:58 +0000 (17:23 +0900)
committermk5004.lee <mk5004.lee@samsung.com>
Thu, 26 Sep 2019 08:34:41 +0000 (17:34 +0900)
Change-Id: Ia37dcfd5a45322a1fb8b3b2351f0906baacb7a75
Signed-off-by: mk5004.lee <mk5004.lee@samsung.com>
include/app_alarm.h
include/app_alarm_extension.h
include/app_alarm_internal.h

index 90f3a80..1b95f04 100644 (file)
@@ -97,10 +97,10 @@ typedef bool (*alarm_registered_alarm_cb)(int alarm_id, void *user_data);
  * @remarks If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, this api does not support exact period and delay for minimizing the wakeups of the device. The system can adjust when the alarm expires.
+ *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, this function does not support exact period and delay for minimizing the wakeups of the device. The system can adjust when the alarm expires.
  *          If you want to trigger an alarm exactly, see @see alarm_schedule_once_after_delay()
  *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif If @a app_control is specified with service-application, the application is only allowed to run on which has Background Category.
- *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
  *          Since 4.0, %http://tizen.org/privilege/appmanager.launch privilege is additionally required.
  *
  * @param[in] app_control The destination app_control to perform a specific task when the alarm is triggered
@@ -110,10 +110,10 @@ typedef bool (*alarm_registered_alarm_cb)(int alarm_id, void *user_data);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP @a app_control is not permitted
  * @see alarm_cancel()
  * @see alarm_cancel_all()
@@ -145,10 +145,10 @@ int alarm_schedule_after_delay(app_control_h app_control, int delay, int period,
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_INVALID_DATE Triggered date is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -166,8 +166,8 @@ int alarm_schedule_at_date(app_control_h app_control, struct tm *date, int perio
  * @remarks If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
- *          The @a app_control only supports UI application with this api. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
+ *          If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          The @a app_control only supports UI application with this function. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
  *          When the alarm is expired, Alarm Manager will turn on LCD to prohibit background jobs.
  *          Since 4.0, %http://tizen.org/privilege/appmanager.launch privilege is additionally required.
  *
@@ -177,10 +177,10 @@ int alarm_schedule_at_date(app_control_h app_control, struct tm *date, int perio
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP @a app_control is not permitted. @a app_control for UI application is only permitted.
  * @see alarm_cancel()
  * @see alarm_cancel_all()
@@ -199,8 +199,8 @@ int alarm_schedule_once_after_delay(app_control_h app_control, int delay, int *a
  * @remarks If application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
- *          The @a app_control only supports UI application with this api. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
+ *          If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          The @a app_control only supports UI application with this function. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
  *          When the alarm is expired, Alarm Manager will turn on LCD to prohibit background jobs.
  *          Since 4.0, %http://tizen.org/privilege/appmanager.launch privilege is additionally required.
  *
@@ -210,10 +210,10 @@ int alarm_schedule_once_after_delay(app_control_h app_control, int delay, int *a
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE   Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval #ALARM_ERROR_INVALID_DATE Triggered date is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP @a app_control is not permitted. @a app_control for UI application is only permitted.
  * @see alarm_cancel()
  * @see alarm_cancel_all()
@@ -235,9 +235,9 @@ int alarm_schedule_once_at_date(app_control_h app_control, struct tm *date, int
  * @remarks If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, The @a app_control only supports UI application with this api. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
+ *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, The @a app_control only supports UI application with this function. If @a app_control is not UI application, #ALARM_ERROR_NOT_PERMITTED_APP returned.
  *          When the alarm is expired, Alarm Manager will turn on LCD to prohibit background jobs.
- *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          Since @if MOBILE 2.4 @elseif WEARABLE 3.0 @endif, If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
  *          Since 4.0, %http://tizen.org/privilege/appmanager.launch privilege is additionally required.
  *
  * @param[in] app_control The destination app_control to perform specific work when the alarm is triggered
@@ -247,10 +247,10 @@ int alarm_schedule_once_at_date(app_control_h app_control, struct tm *date, int
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_INVALID_DATE Triggered date is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP @a app_control is not permitted. @a app_control for UI application is only permitted.
  * @see alarm_cancel()
  * @see alarm_cancel_all()
@@ -268,15 +268,13 @@ int alarm_schedule_with_recurrence_week_flag(app_control_h app_control, struct t
  * @privilege %http://tizen.org/privilege/alarm.get
  * @remarks If the given @a alarm_id is not obtained by using the alarm_schedule_with_recurrence_week_flag() function,
  *          an error (error code #ALARM_ERROR_INVALID_PARAMETER) will occur because this alarm is scheduled with no recurrence.
- *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
- *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
  * @param[in] alarm_id The alarm ID returned when the alarm is scheduled
  * @param[out] week_flag The recurrence days of the week, @a week_flag may be a combination of days, like #ALARM_WEEK_FLAG_TUESDAY | #ALARM_WEEK_FLAG_FRIDAY
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
- * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @see alarm_schedule_with_recurrence_week_flag()
  * @see #alarm_week_flag_e
  */
@@ -292,9 +290,9 @@ int alarm_get_scheduled_recurrence_week_flag(int alarm_id, int *week_flag);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -304,15 +302,15 @@ int alarm_cancel(int alarm_id);
 
 
 /**
- * @brief Cancels all scheduled alarms that are registered by the application that calls this API.
+ * @brief Cancels all scheduled alarms that are registered by the application that calls this function.
  * @since_tizen @if MOBILE 2.3 @elseif WEARABLE 2.3.1 @endif
  * @privlevel public
  * @privilege %http://tizen.org/privilege/alarm.set
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
- * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -331,9 +329,9 @@ int alarm_cancel_all(void);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @post This function invokes alarm_registered_alarm_cb() repeatedly for each registered alarm.
  * @see alarm_registered_alarm_cb()
  */
@@ -351,9 +349,9 @@ int alarm_foreach_registered_alarm(alarm_registered_alarm_cb callback, void *use
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -373,9 +371,9 @@ int alarm_get_scheduled_date(int alarm_id, struct tm *date);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -391,7 +389,6 @@ int alarm_get_scheduled_period(int alarm_id, int *period);
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  */
 int alarm_get_current_time(struct tm *date);
 
@@ -407,9 +404,9 @@ int alarm_get_current_time(struct tm *date);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_OUT_OF_MEMORY Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -435,9 +432,9 @@ int alarm_get_app_control(int alarm_id, app_control_h *app_control);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP @a alarm_id is not permitted
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_once_at_date()
  * @see alarm_schedule_after_delay()
  * @see alarm_schedule_with_recurrence_week_flag()
@@ -455,8 +452,8 @@ int alarm_set_global(int alarm_id, bool global);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
- * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @see alarm_set_global()
  */
 int alarm_get_global(int alarm_id, bool *global);
@@ -479,10 +476,10 @@ int alarm_get_global(int alarm_id, bool *global);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval  #ALARM_ERROR_NONE   Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval  #ALARM_ERROR_INVALID_DATE Triggered date is invalid
  * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -511,11 +508,11 @@ int alarm_schedule_noti_once_at_date(notification_h noti, struct tm *date, int *
  * @param[out] alarm_id The ID which uniquely identifies the scheduled alarm
  * @return @c 0 on success,
  *         otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_INVALID_TIME Triggered time is invalid
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
+ * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -540,11 +537,11 @@ int alarm_schedule_noti_after_delay(notification_h noti, int delay, int period,
  * @param[out] alarm_id The ID which uniquely identifies the scheduled alarm
  * @return @c 0 on success,
  *         otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_INVALID_TIME Triggered time is invalid
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
+ * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -571,10 +568,10 @@ int alarm_schedule_noti_once_after_delay(notification_h noti, int delay, int *al
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_INVALID_DATE Triggered date is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_recurrence_week_flag()
@@ -595,9 +592,9 @@ int alarm_schedule_noti_with_recurrence_week_flag(notification_h noti, struct tm
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
  * @retval #ALARM_ERROR_OUT_OF_MEMORY Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
  * @see alarm_schedule_noti_once_at_date()
  * @see alarm_schedule_noti_after_delay()
  * @see alarm_schedule_noti_once_after_delay()
@@ -621,10 +618,10 @@ int alarm_get_notification(int alarm_id, notification_h *noti);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE               Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL    Failed to connect to an alarm server
  * @retval #ALARM_ERROR_OUT_OF_MEMORY      Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP  App control does not launch an UI application
  */
 int alarm_update_delay(int alarm_id, int delay);
@@ -644,12 +641,12 @@ int alarm_update_delay(int alarm_id, int delay);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE               Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval #ALARM_ERROR_INVALID_TIME       Triggered time is invalid
  * @retval #ALARM_ERROR_INVALID_DATE       Triggered time is invalid
  * @retval #ALARM_ERROR_CONNECTION_FAIL    Failed to connect to an alarm server
  * @retval #ALARM_ERROR_OUT_OF_MEMORY      Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP  App control does not launch an UI application
  */
 int alarm_update_date(int alarm_id, struct tm *date);
@@ -675,10 +672,10 @@ int alarm_update_date(int alarm_id, struct tm *date);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE               Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL    Failed to connect to an alarm server
  * @retval #ALARM_ERROR_OUT_OF_MEMORY      Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  */
 int alarm_update_period(int alarm_id, int period);
 
@@ -705,10 +702,10 @@ int alarm_update_period(int alarm_id, int period);
  * @return @c 0 on success,
  *         otherwise a negative error value
  * @retval #ALARM_ERROR_NONE               Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
  * @retval #ALARM_ERROR_CONNECTION_FAIL    Failed to connect to an alarm server
  * @retval #ALARM_ERROR_OUT_OF_MEMORY      Out of memory
- * @retval #ALARM_ERROR_PERMISSION_DENIED  Permission denied
  * @retval #ALARM_ERROR_NOT_PERMITTED_APP  App control does not launch an UI application
  */
 int alarm_update_week_flag(int alarm_id, int week_flag);
index 2ea34e0..13358f7 100644 (file)
@@ -40,25 +40,25 @@ extern "C" {
  * @details The alarm will go off @a delay seconds later.
  *          To cancel the alarm, call alarm_cancel() with @a alarm_id.
  * @since_tizen 3.0
- * @privlevel  public
- * @privilege  %http://tizen.org/privilege/alarm.set
- * @remarks This API only allows service application which has Background Category to set an exact alarm.
- *                     If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
+ * @privlevel public
+ * @privilege %http://tizen.org/privilege/alarm.set
+ * @remarks This function only allows service application which has Background Category to set an exact alarm.
+ *          If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used r the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
- *          The @a app_control only supports service application which has Background Category with this api.
+ *          If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          The @a app_control only supports service application which has Background Category with this function.
  *
  * @param[in] app_control The destination app_control to perform a specific task when the alarm is triggered
- * @param[in] delay    The amount of time before the execution (in seconds)
+ * @param[in] delay The amount of time before the execution (in seconds)
  * @param[out] alarm_id        The alarm ID that uniquely identifies an alarm
- * @return     @c 0 on success,
- *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_INVALID_TIME Triggered time is invalid
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @return @c 0 on success,
+ *         otherwise a negative error value
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
+ * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -70,25 +70,25 @@ int alarm_schedule_service_once_after_delay(app_control_h app_control, int delay
  * @details The @a date describes the time of the first occurrence.
  *          To cancel the alarm, call alarm_cancel() with @a alarm_id.
  * @since_tizen 3.0
- * @privlevel  public
- * @privilege  %http://tizen.org/privilege/alarm.set
- * @remarks This API only allows service application which has Background Category to set an exact alarm.
- *                     If application is uninstalled after setting an alarm, the alarm is cancelled automatically.
+ * @privlevel public
+ * @privilege %http://tizen.org/privilege/alarm.set
+ * @remarks This function only allows service application which has Background Category to set an exact alarm.
+ *          If application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
- *          The @a app_control only supports service application which has Background Category with this api.
+ *          If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          The @a app_control only supports service application which has Background Category with this function.
  *
- * @param[in]  app_control The destination app_control to perform specific work when the alarm is triggered
- * @param[in]  date    The first active alarm time
- * @param[out] alarm_id        The alarm ID that uniquely identifies an alarm
- * @return     @c 0 on success,
- *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE   Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_INVALID_DATE Triggered date is invalid
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @param[in] app_control The destination app_control to perform specific work when the alarm is triggered
+ * @param[in] date The first active alarm time
+ * @param[out] alarm_id The alarm ID that uniquely identifies an alarm
+ * @return @c 0 on success,
+ *         otherwise a negative error value
+ * @retval #ALARM_ERROR_NONE   Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
+ * @retval #ALARM_ERROR_INVALID_DATE Triggered date is invalid
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()
@@ -96,47 +96,44 @@ int alarm_schedule_service_once_after_delay(app_control_h app_control, int delay
 int alarm_schedule_service_once_at_date(app_control_h app_control, struct tm *date, int *alarm_id);
 
 /**
- * @brief Changes the system time which tranferred by other module
+ * @brief Changes the system time which tranferred by other module.
  * @since_tizen 3.0
- * @privlevel  platform
- * @privilege  %http://tizen.org/privilege/systemsettings.admin
- *
- * @param[in]  new_time epoch time to be set
- * @return     @c 0 on success,
- *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE   Successful
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
+ * @privlevel platform
+ * @privilege %http://tizen.org/privilege/systemsettings.admin
+ * @param[in] new_time epoch time to be set
+ * @return @c 0 on success,
+ *         otherwise a negative error value
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  */
 int alarm_set_systime(int new_time);
 
 /**
- * @brief Changes the system time and compensates the time using propagation delay
+ * @brief Changes the system time and compensates the time using propagation delay.
  * @since_tizen 3.0
- * @privlevel  platform
- * @privilege  %http://tizen.org/privilege/systemsettings.admin
- *
- * @param[in]  new_time system time to be set (seconds, nanoseconds)
- * @param[in]  req_time time to request to change the system time (seconds, nanoseconds)
- * @return     @c 0 on success,
- *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE   Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
+ * @privlevel platform
+ * @privilege %http://tizen.org/privilege/systemsettings.admin
+ * @param[in] new_time system time to be set (seconds, nanoseconds)
+ * @param[in] req_time time to request to change the system time (seconds, nanoseconds)
+ * @return @c 0 on success,
+ *         otherwise a negative error value
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  */
 int alarm_set_systime_with_propagation_delay(struct timespec new_time, struct timespec req_time);
 
 /**
- * @brief Changes the timezone which tranferred by other module
+ * @brief Changes the timezone which tranferred by other module.
  * @since_tizen 3.0
- * @privlevel  platform
- * @privilege  %http://tizen.org/privilege/systemsettings.admin
- *
- * @param[in]  tzpath_str the path to timezone definition file
- * @return     @c 0 on success,
- *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE   Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
+ * @privlevel platform
+ * @privilege %http://tizen.org/privilege/systemsettings.admin
+ * @param[in] tzpath_str the path to timezone definition file
+ * @return @c 0 on success,
+ *         otherwise a negative error value
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_INVALID_PARAMETER Invalid parameter
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  */
 int alarm_set_timezone(char *tzpath_str);
 
index 9a9b5f7..44e45ec 100644 (file)
@@ -43,25 +43,24 @@ extern "C" {
  * @privlevel public
  * @privilege %http://tizen.org/privilege/alarm.set
  * @privilege %http://tizen.org/privilege/appmanager.launch
- * @remarks This API only for in-house applications.
- *          This API only allows service application which has Background Category to set an exact alarm.
+ * @remarks This function only for in-house applications.
+ *          This function only allows service application which has Background Category to set an exact alarm.
  *          If the application is uninstalled after setting an alarm, the alarm is cancelled automatically.
  *          If the operation of @a app_control is not specified, #APP_CONTROL_OPERATION_DEFAULT is used for the launch request.
  *          If the operation of @a app_control is #APP_CONTROL_OPERATION_DEFAULT, the package information is mandatory to explicitly launch the application.
- *          If the appid of @a app_control is not specified, this api is not allowed. In other words, the explicit @a app_control is only allowed.
- *          The @a app_control only supports service application which has Background Category with this api.
- *
+ *          If the appid of @a app_control is not specified, this function is not allowed. In other words, the explicit @a app_control is only allowed.
+ *          The @a app_control only supports service application which has Background Category with this function.
  * @param[in] app_control The destination app_control to perform a specific task when the alarm is triggered
  * @param[in] date The first active alarm time
  * @param[in] period The amount of time between subsequent alarms (in seconds).
  * @param[out] alarm_id The alarm ID that uniquely identifies an alarm
  * @return  @c 0 on success,
  *          otherwise a negative error value
- * @retval  #ALARM_ERROR_NONE Successful
- * @retval  #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
- * @retval  #ALARM_ERROR_INVALID_TIME Triggered time is invalid
- * @retval  #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
- * @retval  #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_NONE Successful
+ * @retval #ALARM_ERROR_PERMISSION_DENIED Permission denied
+ * @retval #ALARM_ERROR_INVALID_PARAMETER  Invalid parameter
+ * @retval #ALARM_ERROR_INVALID_TIME Triggered time is invalid
+ * @retval #ALARM_ERROR_CONNECTION_FAIL Failed to connect to an alarm server
  * @see alarm_cancel()
  * @see alarm_cancel_all()
  * @see alarm_get_scheduled_date()