maximum_usec_per_period = USEC_PER_SEC * PAGE_SIZE /
CYCLES_PER_SECOND / ctx_header_size;
+ // In IEC 61883-6, one isoc packet can transfer events up to the value
+ // of syt interval. This comes from the interval of isoc cycle. As 1394
+ // OHCI controller can generate hardware IRQ per isoc packet, the
+ // interval is 125 usec.
+ // However, there are two ways of transmission in IEC 61883-6; blocking
+ // and non-blocking modes. In blocking mode, the sequence of isoc packet
+ // includes 'empty' or 'NODATA' packets which include no event. In
+ // non-blocking mode, the number of events per packet is variable up to
+ // the syt interval.
+ // Due to the above protocol design, the minimum PCM frames per
+ // interrupt should be double of the value of syt interval, thus it is
+ // 250 usec.
err = snd_pcm_hw_constraint_minmax(runtime,
SNDRV_PCM_HW_PARAM_PERIOD_TIME,
- 5000, maximum_usec_per_period);
+ 250, maximum_usec_per_period);