Each time the HWMON devices are read (e.g. battery voltage) while the
touchscreen is held pressed, extra pen-up and pen-down events are
generated. This is fixed by avoiding the UP event when the touchscreen is
stopped.
Signed-off-by: David Jander <david@protonic.nl>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
msecs_to_jiffies(TS_POLL_PERIOD));
}
- if (ts->pendown) {
+ if (ts->pendown && !ts->stopped) {
struct input_dev *input = ts->input;
input_report_key(input, BTN_TOUCH, 0);