PM / devfreq: exynos-ppmu: Fix refcount leak in of_get_devfreq_events
authorMiaoqian Lin <linmq006@gmail.com>
Thu, 26 May 2022 08:28:56 +0000 (12:28 +0400)
committerChanwoo Choi <cw00.choi@samsung.com>
Wed, 29 Jun 2022 20:11:17 +0000 (05:11 +0900)
of_get_child_by_name() returns a node pointer with refcount
incremented, we should use of_node_put() on it when done.
This function only calls of_node_put() in normal path,
missing it in error paths.
Add missing of_node_put() to avoid refcount leak.

Fixes: f262f28c1470 ("PM / devfreq: event: Add devfreq_event class")
Signed-off-by: Miaoqian Lin <linmq006@gmail.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
drivers/devfreq/event/exynos-ppmu.c

index 9b849d7..a443e7c 100644 (file)
@@ -519,15 +519,19 @@ static int of_get_devfreq_events(struct device_node *np,
 
        count = of_get_child_count(events_np);
        desc = devm_kcalloc(dev, count, sizeof(*desc), GFP_KERNEL);
-       if (!desc)
+       if (!desc) {
+               of_node_put(events_np);
                return -ENOMEM;
+       }
        info->num_events = count;
 
        of_id = of_match_device(exynos_ppmu_id_match, dev);
        if (of_id)
                info->ppmu_type = (enum exynos_ppmu_type)of_id->data;
-       else
+       else {
+               of_node_put(events_np);
                return -EINVAL;
+       }
 
        j = 0;
        for_each_child_of_node(events_np, node) {