x86: Add check for APIC access address for vmentry of L2 guests
authorKrish Sadhukhan <krish.sadhukhan@oracle.com>
Wed, 11 Apr 2018 05:10:16 +0000 (01:10 -0400)
committerPaolo Bonzini <pbonzini@redhat.com>
Thu, 12 Apr 2018 16:36:28 +0000 (18:36 +0200)
According to the sub-section titled 'VM-Execution Control Fields' in the
section titled 'Basic VM-Entry Checks' in Intel SDM vol. 3C, the following
vmentry check must be enforced:

    If the 'virtualize APIC-accesses' VM-execution control is 1, the
    APIC-access address must satisfy the following checks:

- Bits 11:0 of the address must be 0.
- The address should not set any bits beyond the processor's
  physical-address width.

This patch adds the necessary check to conform to this rule. If the check
fails, we cause the L2 VMENTRY to fail which is what the associated unit
test (following patch) expects.

Reviewed-by: Mihai Carabas <mihai.carabas@oracle.com>
Reviewed-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
Reviewed-by: Jim Mattson <jmattson@google.com>
Reviewed-by: Wanpeng Li <wanpengli@tencent.com>
Signed-off-by: Krish Sadhukhan <krish.sadhukhan@oracle.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
arch/x86/kvm/vmx.c

index fe3e13e..a13c603 100644 (file)
@@ -10602,6 +10602,16 @@ static inline bool nested_vmx_prepare_msr_bitmap(struct kvm_vcpu *vcpu,
        return true;
 }
 
+static int nested_vmx_check_apic_access_controls(struct kvm_vcpu *vcpu,
+                                         struct vmcs12 *vmcs12)
+{
+       if (nested_cpu_has2(vmcs12, SECONDARY_EXEC_VIRTUALIZE_APIC_ACCESSES) &&
+           !page_address_valid(vcpu, vmcs12->apic_access_addr))
+               return -EINVAL;
+       else
+               return 0;
+}
+
 static int nested_vmx_check_apicv_controls(struct kvm_vcpu *vcpu,
                                           struct vmcs12 *vmcs12)
 {
@@ -11293,6 +11303,9 @@ static int check_vmentry_prereqs(struct kvm_vcpu *vcpu, struct vmcs12 *vmcs12)
        if (nested_vmx_check_msr_bitmap_controls(vcpu, vmcs12))
                return VMXERR_ENTRY_INVALID_CONTROL_FIELD;
 
+       if (nested_vmx_check_apic_access_controls(vcpu, vmcs12))
+               return VMXERR_ENTRY_INVALID_CONTROL_FIELD;
+
        if (nested_vmx_check_tpr_shadow_controls(vcpu, vmcs12))
                return VMXERR_ENTRY_INVALID_CONTROL_FIELD;