arm64: dts: qcom: msm8998: drop USB PHY clock index
authorJohan Hovold <johan+linaro@kernel.org>
Tue, 5 Jul 2022 11:40:24 +0000 (13:40 +0200)
committerBjorn Andersson <bjorn.andersson@linaro.org>
Thu, 7 Jul 2022 02:39:15 +0000 (21:39 -0500)
The QMP USB PHY provides a single clock so drop the redundant clock
index.

Signed-off-by: Johan Hovold <johan+linaro@kernel.org>
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Signed-off-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20220705114032.22787-7-johan+linaro@kernel.org
arch/arm64/boot/dts/qcom/msm8998.dtsi

index 85bbd4f..02d21bf 100644 (file)
                                      <0xc010600 0x128>,
                                      <0xc010800 0x200>;
                                #phy-cells = <0>;
-                               #clock-cells = <1>;
+                               #clock-cells = <0>;
                                clocks = <&gcc GCC_USB3_PHY_PIPE_CLK>;
                                clock-names = "pipe0";
                                clock-output-names = "usb3_phy_pipe_clk_src";