IIO: bmp280-core.c: fix error in humidity calculation
authorAndreas Klinger <ak@it-klinger.de>
Mon, 10 Apr 2017 17:00:01 +0000 (19:00 +0200)
committerJonathan Cameron <jic23@kernel.org>
Fri, 14 Apr 2017 15:54:49 +0000 (16:54 +0100)
While calculating the compensation of the humidity there are negative values
interpreted as unsigned because of unsigned variables used.  These values as
well as the constants need to be casted to signed as indicated by the
documentation of the sensor.

Signed-off-by: Andreas Klinger <ak@it-klinger.de>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Reviewed-by: Matt Ranostay <matt.ranostay@konsulko.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
drivers/iio/pressure/bmp280-core.c

index 4d18826..d82b788 100644 (file)
@@ -175,11 +175,12 @@ static u32 bmp280_compensate_humidity(struct bmp280_data *data,
        }
        H6 = sign_extend32(tmp, 7);
 
-       var = ((s32)data->t_fine) - 76800;
-       var = ((((adc_humidity << 14) - (H4 << 20) - (H5 * var)) + 16384) >> 15)
-               * (((((((var * H6) >> 10) * (((var * H3) >> 11) + 32768)) >> 10)
-               + 2097152) * H2 + 8192) >> 14);
-       var -= ((((var >> 15) * (var >> 15)) >> 7) * H1) >> 4;
+       var = ((s32)data->t_fine) - (s32)76800;
+       var = ((((adc_humidity << 14) - (H4 << 20) - (H5 * var))
+               + (s32)16384) >> 15) * (((((((var * H6) >> 10)
+               * (((var * (s32)H3) >> 11) + (s32)32768)) >> 10)
+               + (s32)2097152) * H2 + 8192) >> 14);
+       var -= ((((var >> 15) * (var >> 15)) >> 7) * (s32)H1) >> 4;
 
        return var >> 12;
 };