hwmon: (corsair-psu) add reporting of rail mode via debugfs
authorWilken Gottwalt <wilken.gottwalt@posteo.net>
Thu, 11 Aug 2022 08:26:37 +0000 (08:26 +0000)
committerGuenter Roeck <linux@roeck-us.net>
Mon, 19 Sep 2022 13:17:05 +0000 (06:17 -0700)
Add reporting if the PSU is running in single or multi rail mode via
ocpmode debugfs entry. Also update the documentation and driver comments
accordingly.

Signed-off-by: Wilken Gottwalt <wilken.gottwalt@posteo.net>
Link: https://lore.kernel.org/r/YvS9PZKr0xqFqJny@monster.localdomain
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Documentation/hwmon/corsair-psu.rst
drivers/hwmon/corsair-psu.c

index e8378e7a1d8c089c5dc311e6743fc5511ce9889b..c3a76305c5872cab76a50119c1f6a581e59518b5 100644 (file)
@@ -86,8 +86,9 @@ Debugfs entries
 ---------------
 
 =======================        ========================================================
-uptime                 Current uptime of the psu
+ocpmode                 Single or multi rail mode of the PCIe power connectors
+product                 Product name of the psu
+uptime                 Session uptime of the psu
 uptime_total           Total uptime of the psu
 vendor                 Vendor name of the psu
-product                        Product name of the psu
 =======================        ========================================================
index 14389fd7afb896a9a4032d640b3418e810880d9e..c99e4c6afc2d4df34aa4ebf412cb9692619514a8 100644 (file)
@@ -55,6 +55,7 @@
 #define SECONDS_PER_DAY                (SECONDS_PER_HOUR * 24)
 #define RAIL_COUNT             3 /* 3v3 + 5v + 12v */
 #define TEMP_COUNT             2
+#define OCP_MULTI_RAIL         0x02
 
 #define PSU_CMD_SELECT_RAIL    0x00 /* expects length 2 */
 #define PSU_CMD_RAIL_VOLTS_HCRIT 0x40 /* the rest of the commands expect length 3 */
 #define PSU_CMD_RAIL_WATTS     0x96
 #define PSU_CMD_VEND_STR       0x99
 #define PSU_CMD_PROD_STR       0x9A
-#define PSU_CMD_TOTAL_WATTS    0xEE
 #define PSU_CMD_TOTAL_UPTIME   0xD1
 #define PSU_CMD_UPTIME         0xD2
+#define PSU_CMD_OCPMODE                0xD8
+#define PSU_CMD_TOTAL_WATTS    0xEE
 #define PSU_CMD_INIT           0xFE
 
 #define L_IN_VOLTS             "v_in"
@@ -268,6 +270,7 @@ static int corsairpsu_get_value(struct corsairpsu_data *priv, u8 cmd, u8 rail, l
                break;
        case PSU_CMD_TOTAL_UPTIME:
        case PSU_CMD_UPTIME:
+       case PSU_CMD_OCPMODE:
                *val = tmp;
                break;
        default:
@@ -660,6 +663,29 @@ static int product_show(struct seq_file *seqf, void *unused)
 }
 DEFINE_SHOW_ATTRIBUTE(product);
 
+static int ocpmode_show(struct seq_file *seqf, void *unused)
+{
+       struct corsairpsu_data *priv = seqf->private;
+       long val;
+       int ret;
+
+       /*
+        * The rail mode is switchable on the fly. The RAW interface can be used for this. But it
+        * will not be included here, because I consider it somewhat dangerous for the health of the
+        * PSU. The returned value can be a bogus one, if the PSU is in the process of switching and
+        * getting of the value itself can also fail during this. Because of this every other value
+        * than OCP_MULTI_RAIL can be considered as "single rail".
+        */
+       ret = corsairpsu_get_value(priv, PSU_CMD_OCPMODE, 0, &val);
+       if (ret < 0)
+               seq_puts(seqf, "N/A\n");
+       else
+               seq_printf(seqf, "%s\n", (val == OCP_MULTI_RAIL) ? "multi rail" : "single rail");
+
+       return 0;
+}
+DEFINE_SHOW_ATTRIBUTE(ocpmode);
+
 static void corsairpsu_debugfs_init(struct corsairpsu_data *priv)
 {
        char name[32];
@@ -671,6 +697,7 @@ static void corsairpsu_debugfs_init(struct corsairpsu_data *priv)
        debugfs_create_file("uptime_total", 0444, priv->debugfs, priv, &uptime_total_fops);
        debugfs_create_file("vendor", 0444, priv->debugfs, priv, &vendor_fops);
        debugfs_create_file("product", 0444, priv->debugfs, priv, &product_fops);
+       debugfs_create_file("ocpmode", 0444, priv->debugfs, priv, &ocpmode_fops);
 }
 
 #else