The reset-simple driver can be now used on DesignWare IPs by
default by selecting the following compatible strings:
- snps,dw-high-reset for active high resets inputs
- snps,dw-low-reset for active low resets inputs
Signed-off-by: Gustavo Pimentel <gustavo.pimentel@synopsys.com>
Signed-off-by: Luis Oliveira <luis.oliveira@synopsys.com>
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
config RESET_SIMPLE
bool "Simple Reset Controller Driver" if COMPILE_TEST
- default ARCH_STM32 || ARCH_STRATIX10 || ARCH_SUNXI || ARCH_ZX || ARCH_ASPEED || ARCH_BITMAIN
+ default ARCH_STM32 || ARCH_STRATIX10 || ARCH_SUNXI || ARCH_ZX || ARCH_ASPEED || ARCH_BITMAIN || ARC
help
This enables a simple reset controller driver for reset lines that
that can be asserted and deasserted by toggling bits in a contiguous,
{ .compatible = "aspeed,ast2500-lpc-reset" },
{ .compatible = "bitmain,bm1880-reset",
.data = &reset_simple_active_low },
+ { .compatible = "snps,dw-high-reset" },
+ { .compatible = "snps,dw-low-reset",
+ .data = &reset_simple_active_low },
{ /* sentinel */ },
};