elm/scrollable: avoid unnecessary edje recalcs
authorMike Blumenkrantz <zmike@samsung.com>
Tue, 16 Jul 2019 19:30:09 +0000 (15:30 -0400)
committerSangHyeon Jade Lee <sh10233.lee@samsung.com>
Tue, 23 Jul 2019 05:02:34 +0000 (14:02 +0900)
in this case we just want to trigger pending edje calcs and not force new
ones. this avoids doing a full edje recalc constantly when scrolling

@fix

Reviewed-by: Cedric BAIL <cedric.bail@free.fr>
Differential Revision: https://phab.enlightenment.org/D9335

src/lib/elementary/elm_interface_scrollable.c

index bdf929b..7764148 100644 (file)
@@ -1617,7 +1617,10 @@ _elm_interface_scrollable_content_viewport_geometry_get(const Eo *obj EINA_UNUSE
 {
    if (!sid->pan_obj || !sid->edje_obj) return;
 
-   edje_object_calc_force(sid->edje_obj);
+   /* we want to trigger any pending edje recalcs here but we don't strictly need to
+    * trigger one if it isn't necessary
+    */
+   efl_canvas_group_calculate(sid->edje_obj);
    evas_object_geometry_get(sid->pan_obj, x, y, w, h);
 }