The Data Address Watchpoint Register (DAWR) on POWER8 can take a 512
byte range but this range must not cross a 512 byte boundary.
Unfortunately we were off by one when calculating the end of the region,
hence we were not allowing some breakpoint regions which were actually
valid. This fixes this error.
Signed-off-by: Michael Neuling <mikey@neuling.org>
Reported-by: Edjunior Barbosa Machado <emachado@linux.vnet.ibm.com>
Cc: stable@vger.kernel.org # 3.9+
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
length_max = 512 ; /* 64 doublewords */
/* DAWR region can't cross 512 boundary */
if ((bp->attr.bp_addr >> 10) !=
- ((bp->attr.bp_addr + bp->attr.bp_len) >> 10))
+ ((bp->attr.bp_addr + bp->attr.bp_len - 1) >> 10))
return -EINVAL;
}
if (info->len >