To get 100 % duty cycle (always high), pulse width needs to be set to
256.
Signed-off-by: Victor(Weiguo) Pan <wpan@nvidia.com>
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
* per (1 << PWM_DUTY_WIDTH) cycles and make sure to round to the
* nearest integer during division.
*/
- c = duty_ns * ((1 << PWM_DUTY_WIDTH) - 1) + period_ns / 2;
+ c = duty_ns * (1 << PWM_DUTY_WIDTH) + period_ns / 2;
do_div(c, period_ns);
val = (u32)c << PWM_DUTY_SHIFT;