When checking if the transaction is destructive, we need to check if the
previously installed job is a superset of the new job (and hence the new
job will fold into the installed one without changing it), not the other
way around.
assert(!j->transaction_next);
if (j->unit->job && (mode == JOB_FAIL || j->unit->job->irreversible) &&
- !job_type_is_superset(j->type, j->unit->job->type))
+ !job_type_is_superset(j->unit->job->type, j->type))
return sd_bus_error_setf(e, BUS_ERROR_TRANSACTION_IS_DESTRUCTIVE,