Without this patch we can't establish a SCO connection with this
adapter.
This adapter is named "IMC Networks" under lsusb.
T: Bus=01 Lev=01 Prnt=01 Port=07 Cnt=02 Dev#= 3 Spd=12 MxCh= 0
D: Ver= 1.10 Cls=e0(wlcon) Sub=01 Prot=01 MxPS=64 #Cfgs= 1
P: Vendor=13d3 ProdID=3496 Rev= 0.01
C:* #Ifs= 2 Cfg#= 1 Atr=e0 MxPwr=100mA
I:* If#= 0 Alt= 0 #EPs= 3 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=81(I) Atr=03(Int.) MxPS= 16 Ivl=1ms
E: Ad=82(I) Atr=02(Bulk) MxPS= 64 Ivl=0ms
E: Ad=02(O) Atr=02(Bulk) MxPS= 64 Ivl=0ms
I:* If#= 1 Alt= 0 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 0 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 0 Ivl=1ms
I: If#= 1 Alt= 1 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 9 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 9 Ivl=1ms
I: If#= 1 Alt= 2 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 17 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 17 Ivl=1ms
I: If#= 1 Alt= 3 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 25 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 25 Ivl=1ms
I: If#= 1 Alt= 4 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 33 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 33 Ivl=1ms
I: If#= 1 Alt= 5 #EPs= 2 Cls=e0(wlcon) Sub=01 Prot=01 Driver=btusb
E: Ad=83(I) Atr=01(Isoc) MxPS= 49 Ivl=1ms
E: Ad=03(O) Atr=01(Isoc) MxPS= 49 Ivl=1ms
Signed-off-by: João Paulo Rechi Vita <jprvita@endlessm.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
{ USB_DEVICE(0x04ca, 0x3015), .driver_info = BTUSB_QCA_ROME },
{ USB_DEVICE(0x04ca, 0x3016), .driver_info = BTUSB_QCA_ROME },
{ USB_DEVICE(0x04ca, 0x301a), .driver_info = BTUSB_QCA_ROME },
+ { USB_DEVICE(0x13d3, 0x3496), .driver_info = BTUSB_QCA_ROME },
/* Broadcom BCM2035 */
{ USB_DEVICE(0x0a5c, 0x2009), .driver_info = BTUSB_BCM92035 },