Fix logical error code 86/240786/1
authorJihoon Kim <jihoon48.kim@samsung.com>
Tue, 11 Aug 2020 10:38:10 +0000 (19:38 +0900)
committerJihoon Kim <jihoon48.kim@samsung.com>
Tue, 11 Aug 2020 10:38:12 +0000 (19:38 +0900)
Expression 'portrait_line < 0' is always false , which may be caused by a logical error

Change-Id: I0ee7ccbf96a0c66c25d11b221dab1bebf297f2c7
Signed-off-by: Jihoon Kim <jihoon48.kim@samsung.com>
inputmethod/src/inputmethod.cpp

index 4706d71..b2b9e8f 100644 (file)
@@ -2885,11 +2885,6 @@ EXPORT_API int ime_set_candidate_style(scim::ISF_CANDIDATE_PORTRAIT_LINE_T portr
 {
     ime_error_e retVal = IME_ERROR_NONE;
 
-    if (portrait_line < 0 || mode < 0) {
-        LOGW("IME_ERROR_INVALID_PARAMETER");
-        return IME_ERROR_INVALID_PARAMETER;
-    }
-
     if (!g_running) {
         LOGW("IME_ERROR_NOT_RUNNING");
         return IME_ERROR_NOT_RUNNING;