leds: lm3692x: Use flags from LM3692X_BRT_CTRL
authorGuido Günther <agx@sigxcpu.org>
Sat, 21 Sep 2019 21:12:12 +0000 (14:12 -0700)
committerPavel <pavel@ucw.cz>
Sun, 3 Nov 2019 16:38:04 +0000 (17:38 +0100)
Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB
since the later is a flag for the PWM register. The
actual register value remains unchanged.

Signed-off-by: Guido Günther <agx@sigxcpu.org>
Reviewed-by: Dan Murphy <dmurphy@ti.com>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Pavel Machek <pavel@ucw.cz>
drivers/leds/leds-lm3692x.c

index a57b157..8b40810 100644 (file)
@@ -269,7 +269,7 @@ static int lm3692x_init(struct lm3692x_led *led)
                goto out;
 
        ret = regmap_write(led->regmap, LM3692X_BRT_CTRL,
-                       LM3692X_BL_ADJ_POL | LM3692X_PWM_HYSTER_4LSB);
+                       LM3692X_BL_ADJ_POL | LM3692X_RAMP_EN);
        if (ret)
                goto out;