ovl->manager = mgr;
dss_clk_enable(DSS_CLK_ICK | DSS_CLK_FCK);
- /* XXX: on manual update display, in auto update mode, a bug happens
- * here. When an overlay is first enabled on LCD, then it's disabled,
- * and the manager is changed to TV, we sometimes get SYNC_LOST_DIGIT
- * errors. Waiting before changing the channel_out fixes it. I'm
- * guessing that the overlay is still somehow being used for the LCD,
- * but I don't understand how or why. */
- msleep(40);
+ /* XXX: When there is an overlay on a DSI manual update display, and
+ * the overlay is first disabled, then moved to tv, and enabled, we
+ * seem to get SYNC_LOST_DIGIT error.
+ *
+ * Waiting doesn't seem to help, but updating the manual update display
+ * after disabling the overlay seems to fix this. This hints that the
+ * overlay is perhaps somehow tied to the LCD output until the output
+ * is updated.
+ *
+ * Userspace workaround for this is to update the LCD after disabling
+ * the overlay, but before moving the overlay to TV.
+ */
dispc_set_channel_out(ovl->id, mgr->id);
dss_clk_disable(DSS_CLK_ICK | DSS_CLK_FCK);