The fw now indicates missing BA with ampdu_ack_len=0.
This will make the whole aggregation being marked
as failed, although it's most likely not the case (and
only the BA itself was failed).
Consider this case as a single tx failure.
Signed-off-by: Eyal Shapira <eyalx.shapira@intel.com>
Signed-off-by: Eliad Peller <eliadx.peller@intel.com>
Reviewed-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: Emmanuel Grumbach <emmanuel.grumbach@intel.com>
* first index into rate scale table.
*/
if (info->flags & IEEE80211_TX_STAT_AMPDU) {
+ /* ampdu_ack_len = 0 marks no BA was received. In this case
+ * treat it as a single frame loss as we don't want the success
+ * ratio to dip too quickly because a BA wasn't received
+ */
+ if (info->status.ampdu_ack_len == 0)
+ info->status.ampdu_len = 1;
+
ucode_rate = le32_to_cpu(table->rs_table[0]);
rs_rate_from_ucode_rate(ucode_rate, info->band, &rate);
rs_collect_tx_data(lq_sta, curr_tbl, rate.index,