Observed when disabling LEGITIMIZE_RELOAD_ADDRESS for
cris-elf: the current code doesn't handle the post-cc0
parallel-with-clobber-of-cc0 sets, dropping down into the
fatal_insn call. Following the code, it's obvious that the
variable "set" is always NULL at the call. The intended
parameter is "in".
* reload1.cc (gen_reload): Correct rtx parameter for fatal_insn
"failure trying to reload" call.
return insn;
}
- fatal_insn ("failure trying to reload:", set);
+ fatal_insn ("failure trying to reload:", in);
}
/* If IN is a simple operand, use gen_move_insn. */
else if (OBJECT_P (in) || GET_CODE (in) == SUBREG)