Read Local OOB Data command can take more than 1 second on some chips.
e.g. on CSR 0a12:0001 first call to Read Local OOB Data after reset
takes about 1300ms resulting in tx timeout error.
[27698.368655] Bluetooth: hci0 command 0x0c57 tx timeout
2012-10-31 15:53:36.178585 < HCI Command: Read Local OOB Data (0x03|0x0057) plen 0
2012-10-31 15:53:37.496996 > HCI Event: Command Complete (0x0e) plen 36
Read Local OOB Data (0x03|0x0057) ncmd 1
status 0x00
hash 0x92219d9b447f2aa9dc12dda2ae7bae6a
randomizer 0xb1948d0febe4ea38ce85c4e66313beba
Signed-off-by: Szymon Janc <szymon.janc@tieto.com>
Signed-off-by: Gustavo Padovan <gustavo.padovan@collabora.co.uk>
#define HCI_DISCONN_TIMEOUT msecs_to_jiffies(2000) /* 2 seconds */
#define HCI_PAIRING_TIMEOUT msecs_to_jiffies(60000) /* 60 seconds */
#define HCI_INIT_TIMEOUT msecs_to_jiffies(10000) /* 10 seconds */
-#define HCI_CMD_TIMEOUT msecs_to_jiffies(1000) /* 1 second */
+#define HCI_CMD_TIMEOUT msecs_to_jiffies(2000) /* 2 seconds */
#define HCI_ACL_TX_TIMEOUT msecs_to_jiffies(45000) /* 45 seconds */
#define HCI_AUTO_OFF_TIMEOUT msecs_to_jiffies(2000) /* 2 seconds */