The START STOP UNIT command will only eject/load media if
power condition is zero.
If power condition is !0 then LOEJ and START will be ignored.
From MMC (sbc contains similar wordings too)
The Power Conditions field requests the block device to be placed
in the power condition defined in
Table 558. If this field has a value other than 0h then the Start
and LoEj bits shall be ignored.
Signed-off-by: Ronnie Sahlberg <ronniesahlberg@gmail.com>
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
int sense;
bool start = buf[4] & 1;
bool loej = buf[4] & 2; /* load on start, eject on !start */
+ int pwrcnd = buf[4] & 0xf0;
+
+ if (pwrcnd) {
+ /* eject/load only happens for power condition == 0 */
+ return;
+ }
if (loej) {
if (!start && !s->tray_open && s->tray_locked) {