dt-bindings: mfd: rohm,bd71847-pmic: Correct clock properties requirements
authorKrzysztof Kozlowski <krzk@kernel.org>
Fri, 4 Sep 2020 15:23:59 +0000 (17:23 +0200)
committerRob Herring <robh@kernel.org>
Mon, 14 Sep 2020 22:49:09 +0000 (16:49 -0600)
The input clock and number of clock provider cells are not required for
the PMIC to operate.  They are needed only for the optional bd718x7
clock driver.

Add also clock-output-names as driver takes use of it.

This fixes dtbs_check warnings like:

    arch/arm64/boot/dts/freescale/imx8mn-ddr4-evk.dt.yaml: pmic@4b: 'clocks' is a required property
    arch/arm64/boot/dts/freescale/imx8mn-ddr4-evk.dt.yaml: pmic@4b: '#clock-cells' is a required property

Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Acked-by: Matti Vaittinen <matti.vaittinen@fi.rohmeurope.com>
Signed-off-by: Rob Herring <robh@kernel.org>
Documentation/devicetree/bindings/mfd/rohm,bd71847-pmic.yaml

index 77bcca2..5d53105 100644 (file)
@@ -38,6 +38,9 @@ properties:
   "#clock-cells":
     const: 0
 
+  clock-output-names:
+    maxItems: 1
+
 # The BD71847 abd BD71850 support two different HW states as reset target
 # states. States are called as SNVS and READY. At READY state all the PMIC
 # power outputs go down and OTP is reload. At the SNVS state all other logic
@@ -116,12 +119,14 @@ required:
   - compatible
   - reg
   - interrupts
-  - clocks
-  - "#clock-cells"
   - regulators
 
 additionalProperties: false
 
+dependencies:
+  '#clock-cells': [clocks]
+  clocks: ['#clock-cells']
+
 examples:
   - |
     #include <dt-bindings/interrupt-controller/irq.h>