Use the preferred form of branch-and-link for finding the current
address so objtool doesn't think it is an unannotated intra-function
call.
Signed-off-by: Nicholas Piggin <npiggin@gmail.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://msgid.link/20230407040924.231023-1-npiggin@gmail.com
_zimage_start_lib:
/* Work out the offset between the address we were linked at
and the address where we're running. */
- bl .+4
+ bcl 20,31,.+4
p_base: mflr r10 /* r10 now points to runtime addr of p_base */
#ifndef __powerpc64__
/* grab the link address of the dynamic section in r11 */
mtsrr1 r10
/* Load FW address, set LR to label 1, and jump to FW */
- bl 0f
+ bcl 20,31,0f
0: mflr r10
addi r11,r10,(1f-0b)
mtlr r11