When create a raid5 using assume-clean and echo check or repair to
sync_action.Then component disks did not operated IO but the raid
check/resync faster than normal.
Because the judgement in function analyse_stripe():
if (do_recovery ||
sh->sector >= conf->mddev->recovery_cp)
s->syncing = 1;
else
s->replacing = 1;
When check or repair,the recovery_cp == MaxSectore,so syncing equal zero
not one.
This bug was introduced by commit
9a3e1101b827
md/raid5: detect and handle replacements during recovery.
so this patch is suitable for 3.3-stable.
Cc: stable@vger.kernel.org
Signed-off-by: majianpeng <majianpeng@gmail.com>
Signed-off-by: NeilBrown <neilb@suse.de>
/* If there is a failed device being replaced,
* we must be recovering.
* else if we are after recovery_cp, we must be syncing
+ * else if MD_RECOVERY_REQUESTED is set, we also are syncing.
* else we can only be replacing
* sync and recovery both need to read all devices, and so
* use the same flag.
*/
if (do_recovery ||
- sh->sector >= conf->mddev->recovery_cp)
+ sh->sector >= conf->mddev->recovery_cp ||
+ test_bit(MD_RECOVERY_REQUESTED, &(conf->mddev->recovery)))
s->syncing = 1;
else
s->replacing = 1;