clk: x86: Use dynamic con_id string during clk registration
authorAjit Kumar Pandey <AjitKumar.Pandey@amd.com>
Sun, 12 Dec 2021 18:05:26 +0000 (23:35 +0530)
committerStephen Boyd <sboyd@kernel.org>
Fri, 7 Jan 2022 01:57:52 +0000 (17:57 -0800)
Replace hard coded con_id string with fch_data->name. We have clk
consumers looking up with different clock names, hence use dynamic
con_id string during clk lookup registration. fch_data->name will
be initialized in acpi driver based on fmw property value.

Signed-off-by: Ajit Kumar Pandey <AjitKumar.Pandey@amd.com>
Reviewed-by: Mario Limonciello <Mario.Limonciello@amd.com>
Link: https://lore.kernel.org/r/20211212180527.1641362-5-AjitKumar.Pandey@amd.com
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
drivers/clk/x86/clk-fch.c

index 6a726420bfcb42ea6a918ab58ce9736350a6b504..d41d519b9c2ba0cd04ab209c3159277374136986 100644 (file)
@@ -75,7 +75,7 @@ static int fch_clk_probe(struct platform_device *pdev)
                        OSCCLKENB, CLK_GATE_SET_TO_DISABLE, NULL);
 
                devm_clk_hw_register_clkdev(&pdev->dev, hws[ST_CLK_GATE],
-                       "oscout1", NULL);
+                                           fch_data->name, NULL);
        } else {
                hws[CLK_48M_FIXED] = clk_hw_register_fixed_rate(NULL, "clk48MHz",
                        NULL, 0, 48000000);
@@ -85,7 +85,7 @@ static int fch_clk_probe(struct platform_device *pdev)
                        OSCCLKENB, CLK_GATE_SET_TO_DISABLE, NULL);
 
                devm_clk_hw_register_clkdev(&pdev->dev, hws[CLK_GATE_FIXED],
-                       "oscout1", NULL);
+                                           fch_data->name, NULL);
        }
 
        pci_dev_put(rdev);