The powerpc fallocate compat syscall handler is identical to the
generic implementation provided by commit
59c10c52f573f ("riscv:
compat: syscall: Add compat_sys_call_table implementation"), and as
such can be removed in favour of the generic implementation.
A future patch series will replace more architecture-defined syscall
handlers with generic implementations, dependent on introducing generic
implementations that are compatible with powerpc and arm's parameter
reorderings.
Reported-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Rohan McLure <rmclure@linux.ibm.com>
Reviewed-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/20220921065605.1051927-11-rmclure@linux.ibm.com
int compat_sys_truncate64(const char __user *path, u32 reg4,
unsigned long len1, unsigned long len2);
-long compat_sys_fallocate(int fd, int mode, u32 offset1, u32 offset2, u32 len1, u32 len2);
-
int compat_sys_ftruncate64(unsigned int fd, u32 reg4, unsigned long len1,
unsigned long len2);
#define __ARCH_WANT_SYS_UTIME
#define __ARCH_WANT_SYS_NEWFSTATAT
#define __ARCH_WANT_COMPAT_STAT
+#define __ARCH_WANT_COMPAT_FALLOCATE
#define __ARCH_WANT_COMPAT_SYS_SENDFILE
#endif
#define __ARCH_WANT_SYS_FORK
return ksys_truncate(path, merge_64(len1, len2));
}
-long compat_sys_fallocate(int fd, int mode, u32 offset1, u32 offset2,
- u32 len1, u32 len2)
-{
- return ksys_fallocate(fd, mode, merge_64(offset1, offset2),
- merge_64(len1, len2));
-}
-
int compat_sys_ftruncate64(unsigned int fd, u32 reg4, unsigned long len1,
unsigned long len2)
{