rt2800: validate step value for temperature compensation
authorStanislaw Gruszka <sgruszka@redhat.com>
Thu, 25 Oct 2012 07:51:39 +0000 (09:51 +0200)
committerJohn W. Linville <linville@tuxdriver.com>
Tue, 30 Oct 2012 19:58:54 +0000 (15:58 -0400)
Some hardware has correct (!= 0xff) value of tssi_bounds[4] in the
EEPROM, but step is equal to 0xff. This results on ridiculous delta
calculations and completely broke TX power settings.

Reported-and-tested-by: Pavel Lucik <pavel.lucik@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com>
Acked-by: Ivo van Doorn <IvDoorn@gmail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
drivers/net/wireless/rt2x00/rt2800lib.c

index 01dc889..59474ae 100644 (file)
@@ -2449,7 +2449,7 @@ static int rt2800_get_gain_calibration_delta(struct rt2x00_dev *rt2x00dev)
        /*
         * Check if temperature compensation is supported.
         */
-       if (tssi_bounds[4] == 0xff)
+       if (tssi_bounds[4] == 0xff || step == 0xff)
                return 0;
 
        /*