If an error occurs in the L3 on any other initiator than MPU,
the interrupt goes unhandled given that the 'base' register
was calculated with the initialized err_source value (which
coincidentally points to MPU) and not with the actual source
of the error.
Removed parenthesis that are not needed for the touched lines.
Signed-off-by: Omar Ramirez Luna <omar.ramirez@ti.com>
Acked-by: Santosh Shilimkar <santosh.shilimkar@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
/* No timeout error for debug sources */
}
- base = ((l3->rt) + (*(omap3_l3_bases[int_type] + err_source)));
-
/* identify the error source */
for (err_source = 0; !(status & (1 << err_source)); err_source++)
;
+
+ base = l3->rt + *(omap3_l3_bases[int_type] + err_source);
error = omap3_l3_readll(base, L3_ERROR_LOG);
if (error) {